ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias
X24641.......................................–65°C to +135°C
Storage Temperature ........................–65°C to +150°C
Voltage on any Pin with
Respect to VSS.................................... –1V to +7V
D.C. Output Current ..............................................5mA
Lead Temperature
(Soldering, 10 seconds) .............................. 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation
of the device at these or any other conditions above
those indicated in the operational sections of this
specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may
affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Industrial
Min.
0°C
–40°C
D.C. OPERATING CHARACTERISTICS
Max.
+70°C
+85°C
7026 FRM T04
Supply Voltage
X24641
X24641–2.5
X24641–1.8
Limits
4.5V to 5.5V
2.5V to 5.5V
1.8V to 3.6V
7026 FRM T05
Limits
Symbol
Parameter
Min.
Max. Units
Test Conditions
ICC1
ICC2
ISB1(1)
ISB2(1)
ILI
ILO
VlL(2)
VIH(2)
VOL
Vhys(3)
VCC Supply Current (Read)
VCC Supply Current
(Write)
VCC Standby Current
VCC Standby Current
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
Hysteresis of Schmitt
Trigger Inputs
–0.5
VCC x 0.7
VCC x 0.05
1
3
3
1
10
10
VCC x 0.3
VCC + 0.5
0.4
mA SCL = VCC X 0.1/VCC X 0.9 Levels
mA @ 400KHz, SDA = Open, All Other
Inputs = VSS or VCC – 0.3V
µA SCL = SDA = VCC – 0.3V,
All Other Inputs = VSS or VCC – 0.3V,
VCC = 5V ± 10%
µA SCL = SDA = VCC – 0.1V,
All Other Inputs = VSS or VCC – 0.1V,
VCC = 1.8V
µA VIN = VSS to VCC
µA VOUT = VSS to VCC
V
V
V IOL = 3mA
V
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V
7026 FRM T06.1
Symbol
CI/O(3)
CIN(3)
Parameter
Input/Output Capacitance (SDA)
Input Capacitance (S0, S1, S2, SCL,WP)
Notes: (1) Must perform a stop command prior to measurement.
(2) VIL min. and VIH max. are for reference only and are not 100% tested.
(3) This parameter is periodically sampled and not 100% tested.
Max.
8
6
Units
pF
pF
Test Conditions
VI/O = 0V
VIN = 0V
7026 FRM T07