English
Language : 

X9250 Datasheet, PDF (7/21 Pages) Xicor Inc. – Quad Digitally Controlled Potentiometers (XDCP)
X9250
Figure 8. Increment/Decrement Timing Limits
SCK
SI
tWRID
VW/RW
Voltage Out
INC/DEC CMD Issued
Table 1. Instruction Set
Instruction Set
Instruction
I3 I2 I1 I0 R1 R0 P1 P0
Operation
Read Wiper Counter
Register
1 0 0 1 0 0 P1 P0 Read the contents of the Wiper Counter
Register pointed to by P1-P0
Write Wiper Counter
Register
1 0 1 0 0 0 P1 P0 Write new value to the Wiper Counter
Register pointed to by P1-P0
Read Data Register
1 0 1 1 R1 R0 P1 P0 Read the contents of the Data Register
pointed to by P1-P0 and R1–R0
Write Data Register
1 1 0 0 R1 R0 P1 P0 Write new value to the Data Register pointed
to by P1-P0 and R1–R0
XFR Data Register to
Wiper Counter Register
1 1 0 1 R1 R0 P1 P0 Transfer the contents of the Data Register
pointed to by R1–R0 to the Wiper Counter
Register pointed to by P1-P0
XFR Wiper Counter
1 1 1 0 R1 R0 P1 P0 Transfer the contents of the Wiper Counter
Register to Data Register
Register pointed to by P1-P0 to the Register
pointed to by R1–R0
Global XFR Data Register 0 0 0 1 R1 R0 0
to Wiper Counter Register
0 Transfer the contents of the Data Registers
pointed to by R1–R0 of all four pots to their
respective Wiper Counter Register
Global XFR Wiper Counter 1 0 0 0 R1 R0 0
Register to Data Register
0 Transfer the contents of all Wiper Counter
Registers to their respective data Registers
pointed to by R1–R0 of all four pots
Increment/Decrement
Wiper Counter Register
0 0 1 0 0 0 P1 P0 Enable Increment/decrement of the Wiper
Counter Register pointed to by P1-P0
Read Status (WIP bit)
0 1 0 1 0 0 0 1 Read the status of the internal write cycle,
by checking the WIP bit.
REV 1.1.5 1/31/03
www.xicor.com
Characteristics subject to change without notice. 7 of 21