English
Language : 

X9241 Datasheet, PDF (6/16 Pages) Xicor Inc. – Quad E2POT™ Nonvolatile Digital Potentiometer
X9241
Table 1. Instruction Set
Instruction Format
Instruction
Read WCR
Write WCR
Read Data
Register
Write Data
Register
XFR Data Reg-
ister to WCR
I3 I2 I1 I0 P1 P0
R1 Ro
Operation
1 0 0 1 1/0(7) 1/0 N/A(8) N/A Read the contents of the Wiper Counter
Register pointed to by P1–P0
1 0 1 0 1/0 1/0 N/A N/A Write new value to the Wiper Counter
Register pointed to by P1–P0
1 0 1 1 1/0 1/0 1/0 1/0 Read the contents of the Register
pointed to by P1–P0 and R1–R0
1 1 0 0 1/0 1/0 1/0 1/0 Write new value to the Register
pointed to by P1–P0 and R1–R0
1 1 0 1 1/0 1/0 1/0 1/0 Transfer the contents of the Register
pointed to by P1–P0 and R1–R0
to its associated WCR
XFR WCR to
Data Register
Global XFR Data
Register to WCR
1 1 1 0 1/0 1/0 1/0 1/0 Transfer the contents of the WCR
pointed to by P1–P0 to the Register
pointed to by R1–R0
0 0 0 1 N/A N/A 1/0 1/0 Transfer the contents of all four Data
Registers pointed to by R1–R0 to their
respective WCR
Global XFR WCR 1 0 0 0 N/A N/A 1/0 1/0 Transfer the contents of all WCRs
to Data Register
to their respective data Registers
pointed to by R1–R0
Increment/Decre- 0 0 1 0 1/0 1/0 N/A N/A Enable Increment/decrement of the
ment Wiper
WCR pointed to by P1–P0
3864 PGM T02.1
Notes: (7) 1/0 = data is one or zero
(8) N/A = Not applicable or don't care; that is, a data register is not involved in the operation and need not be addressed (typical)
Figure 7. Acknowledge Response from Receiver
SCL FROM
MASTER
1
DATA
OUTPUT
FROM
TRANSMITTER
DATA
OUTPUT
FROM
RECEIVER
START
8
9
ACKNOWLEDGE
3864 ILL F14
6