English
Language : 

X24645 Datasheet, PDF (12/18 Pages) Xicor Inc. – Advanced 2-Wire Serial E 2 PROM with Block Lock TM Protection
X24645
A.C. CONDITIONS OF TEST
Input Pulse Levels
Input Rise and
Fall Times
Input and Output
Timing Levels
VCC x 0.1 to VCC x 0.9
10ns
VCC X 0.5
2783 FRM T08
EQUIVALENT A.C. LOAD CIRCUIT
OUTPUT
5V
1.53KΩ
100pF
2783 ILL F16.1
A.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions, unless otherwise specified.)
Read & Write Cycle Limits
Symbol
fSCL
TI
tAA
tBUF
tHD:STA
tLOW
tHIGH
tSU:STA
tHD:DAT
tSU:DAT
tR
tF
tSU:STO
tDH
Parameter
SCL Clock Frequency
Noise Suppression Time
Constant at SCL, SDA Inputs
SCL LOW to SDA Data Out Valid
Time the Bus Must Be Free Before a
New Transmission Can Start
Start Condition Hold Time
Clock LOW Period
Clock HIGH Period
Start Condition Setup Time
(for a Repeated Start Condition)
Data In Hold Time
Data In Setup Time
SDA and SCL Rise Time
SDA and SCL Fall Time
Stop Condition Setup Time
Data Out Hold Time
Min.
0
0.3
4.7
4
4.7
4
4.7
0
250
4.7
300
Max.
100
100
3.5
1
300
Units
KHz
ns
µs
µs
µs
µs
µs
µs
µs
ns
µs
ns
µs
ns
2783 FRM T09.2
POWER-UP TIMING(4)
Symbol
Parameter
Max.
Units
tPUR
Power-up to Read Operation
1
ms
tPUW
Power-up to Write Operation
5
ms
2783 FRM T10
Notes: (4) tPUR and tPUW are the delays required from the time VCC is stable until the specified operation can be initiated. These parameters
are periodically sampled and not 100% tested.
12