X24645
ABSOLUTE MAXIMUM RATINGS*
Temperature under Bias
X24645.......................................–65°C to +135°C
Storage Temperature ........................–65°C to +150°C
Voltage on any Pin with
Respect to VSS.................................... –1V to +7V
D.C. Output Current ..............................................5mA
Lead Temperature
(Soldering, 10 seconds) .............................. 300°C
*COMMENT
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation
of the device at these or any other conditions above
those indicated in the operational sections of this
specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may
affect device reliability.
RECOMMENDED OPERATING CONDITIONS
Temperature
Min.
Max.
Commercial
0°C
+70°C
Industrial
–40°C
+85°C
Military
–55°C
+125°C
2783 FRM T04
D.C. OPERATING CHARACTERISTICS
Supply Voltage
X24645
X24645-2.7
Limits
4.5V to 5.5V
2.7V to 5.5V
2783 FRM T05
Limits
Symbol
ICC1
ICC2
Parameter
VCC Supply Current (Read)
VCC Supply Current (Write)
ISB1(1)
VCC Standby Current
Min.
ISB2(1)
VCC Standby Current
ILI
ILO
VlL(2)
VIH(2)
VOL
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Input HIGH Voltage
Output LOW Voltage
–1
VCC x 0.7
CAPACITANCE TA = +25°C, f = 1MHz, VCC = 5V
Max.
1
3
50
1
10
10
VCC x 0.3
VCC + 0.5
0.4
Units
Test Conditions
mA SCL = VCC X 0.1/VCC X 0.9 Levels
mA
@ 100KHz, SDA = Open, All Other
Inputs = VSS or VCC – 0.3V
µA SCL = SDA = VCC, All Other
Inputs = VSS or VCC – 0.3V,
VCC = 5V ± 10%
µA SCL = SDA = VCC, All Other
Inputs = VSS or VCC – 0.3V,
VCC = 2.7V
µA VIN = VSS to VCC
µA VOUT = VSS to VCC
V
V
V IOL = 3mA, VCC = 4.5V
2783 FRM T06.2
Symbol
CI/O(3)
CIN(3)
Parameter
Input/Output Capacitance (SDA)
Input Capacitance (S1, S2, SCL)
Notes: (1) Must perform a stop command prior to measurement.
(2) VIL min. and VIH max. are for reference only and are not 100% tested.
(3) This parameter is periodically sampled and not 100% tested.
Max.
8
6
Units
pF
pF
Test Conditions
VI/O = 0V
VIN = 0V
2783 FRM T07.1
11