English
Language : 

X9259 Datasheet, PDF (1/25 Pages) Xicor Inc. – Quad Digitally-Controlled (XDCP) Potentiometers
APPLICATION NOTES AND DEVELOPMENT SYSTEM
AVAILABLE
AN99 • AN115 • AN124 •AN133 • AN134 • AN135
Single Supply / Low Power / 256-tap / 2-Wire bus
X9259
Quad Digitally-Controlled (XDCPTM) Potentiometers
FEATURES
• Quad–Four separate potentiometers
• 256 resistor taps/pot–0.4% resolution
• 2-Wire Serial Interface for write, read, and
transfer operations of the potentiometer
• Wiper Resistance, 100Ω typical @ VCC = 5V
• 4 Nonvolatile Data Registers for Each
Potentiometer
• Nonvolatile Storage of Multiple Wiper Positions
• Power On Recall. Loads Saved Wiper Position on
Power Up.
• Standby Current < 5µA Max
• VCC: 2.7V to 5.5V Operation
• 50KΩ, 100KΩ versions of End to End Pot
Resistance
• Endurance: 100,000 Data Changes per Bit per
Register
• 100 yr. Data Retention
• Single Supply Version of X9258
• 24-Lead SOIC, 24-Lead TSSOP, 24-Lead XBGA
• Low Power CMOS
DESCRIPTION
The X9259 integrates 4 digitally controlled
potentiometer (XDCP) on a monolithic CMOS
integrated circuit.
The digital controlled potentiometer is implemented
using 255 resistive elements in a series array. Between
each element are tap points connected to the wiper
terminal through switches. The position of the wiper on
the array is controlled by the user through the 2-Wire
bus interface. Each potentiometer has associated with
it a volatile Wiper Counter Register (WCR) and a four
nonvolatile Data Registers that can be directly written
to and read by the user. The contents of the WCR
controls the position of the wiper on the resistor array
though the switches. Powerup recalls the contents of
the default Data Register (DR0) to the WCR.
The XDCP can be used as a three-terminal
potentiometer or as a two terminal variable resistor in
a wide variety of applications including control,
parameter adjustments, and signal processing.
FUNCTIONAL DIAGRAM
VCC
2-Wire
Bus
Interface
Address
Data
Status
Bus
Interface
and Control
Write
Read
Transfer
Inc/Dec
Control
Power On Recall
Wiper Counter
Registers (WCR)
Data Registers
16 Bytes
RH0
RH1
RH2
RH3
VSS
RW0
RL0 RW1 RL1 RW2
RL2 RW3
RL3
50KΩ or 100KΩ versions
REV 1.2.3 4/30/02
www.xicor.com
Characteristics subject to change without notice. 1 of 25