English
Language : 

WM8326 Datasheet, PDF (84/255 Pages) Wolfson Microelectronics plc – Processor Power Management Subsystem
WM8326
ADDRESS
BIT
LABEL
3:0 LDO11_ON_
VSEL [3:0]
R16520 (4088h)
LDO11 SLEEP
Control
15:13 LDO11_SLP
_SLOT [2:0]
3:0 LDO11_SLP
_VSEL [3:0]
Table 36 LDO Regulator 11 Control
DEFAULT
000
Production Data
DESCRIPTION
LDO11 ON Voltage select
0.80V to 1.55V in 50mV steps
0h = 0.80V
1h = 0.85V
2h = 0.90V
…
Eh = 1.50V
Fh = 1.55V
LDO11 SLEEP Slot select
000 = SLEEP voltage / operating
mode transition in Timeslot 5
001 = Disable in Timeslot 5
010 = Disable in Timeslot 4
011 = Disable in Timeslot 3
100 = Disable in Timeslot 2
101 = Disable in Timeslot 1
110 = SLEEP voltage / operating
mode transition in Timeslot 3
111 = SLEEP voltage / operating
mode transition in Timeslot 1
If LDO11 is assigned to a Hardware
Enable Input, then codes 001-101
select in which timeslot the regulator
enters its SLEEP condition.
LDO11 SLEEP Voltage select
0.80V to 1.55V in 50mV steps
0h = 0.80V
1h = 0.85V
2h = 0.90V
…
Eh = 1.50V
Fh = 1.55V
15.11.4 EXTERNAL POWER ENABLE (EPE) CONTROL
The register controls for configuring the External Power Enable (EPE) outputs are defined in Table
37.
Note that the EPE1_ON_SLOT and EPE2_ON_SLOT fields may also be stored in the integrated OTP
memory. See Section 14 for details.
ADDRESS
R16521 (4089h)
EPE1 Control
BIT
15:13
LABEL
EPE1_ON_S
LOT [2:0]
DEFAULT
000
DESCRIPTION
EPE1 ON Slot select
000 = Do not enable
001 = Enable in Timeslot 1
010 = Enable in Timeslot 2
011 = Enable in Timeslot 3
100 = Enable in Timeslot 4
101 = Enable in Timeslot 5
110 = Controlled by Hardware Enable
1
111 = Controlled by Hardware Enable
2
w
PD, June 2012, Rev 4.0
84