English
Language : 

W27L01 Datasheet, PDF (6/15 Pages) Winbond – 128K X 8 ELECTRICALLY ERASABLE EPROM
W27L01
AC Test Conditions
PARAMETER
Input Pulse Levels
Input Rise and Fall Times
Input and Output Timing Reference Level
Output Load
CONDITIONS
0V to 3.0V
5 nS
1.5V/1.5V
CL = 100 pF, IOH/IOL = -0.1 mA/1.6 mA for Read
IOH/IOL = -0.4 mA/2.1 mA for Program/Erase
AC Test Load and Waveforms
+1.3V
(IN914)
3.3K ohm
DOUT
100 pF (Including Jig and Scope)
Input
3.0V
0V
Test Points
1.5V
Output
Test Points
1.5V
-6-