English
Language : 

W83194BR-903 Datasheet, PDF (23/26 Pages) Winbond – STEPLESS VIA PT/PM MAIN CLOCK GENERATOR
W83194BR-903
9.7 24M, 48M Electrical Characteristics
VDD48= 3.3V ± 5 %, TA = 0°C to +70°C, Test load, Cl=10pF,
PARAMETER
MIN. MAX. UNITS
Rise Time
500 2000
ps
Fall Time
500 2000
ps
Long term jitter
500
ps
Duty Cycle
45
55
%
Pull-Up Current Min
-33
mA
Pull-Up Current Max
-33
mA
Pull-Down Current Min
30
mA
Pull-Down Current Max
38
mA
TEST CONDITIONS
Measure from 0.4V to 2.4V
Measure from 2.4V to 0.4V
Measure 1.5V point
Vout=1.0V
Vout=3.135V
Vout=1.95V
Vout=0.4V
9.8 REF Electrical Characteristics
VDDREF= 3.3V ± 5 %, TA = 0°C to +70°C, Test load, Cl=10pF,
PARAMETER
MIN. MAX. UNITS
Rise Time
1000 4000
ps
Fall Time
1000 4000
ps
Cycle to Cycle jitter
Duty Cycle
Pull-Up Current Min
Pull-Up Current Max
1000
ps
45
55
%
-33
mA
-33
mA
Pull-Down Current Min
Pull-Down Current Max
30
mA
38
mA
TEST CONDITIONS
Measure from 0.4V to 2.4V
Measure from 2.4V to 0.4V
Measure 1.5V point
Vout=1.0V
Vout=3.135V
Vout=1.95V
Vout=0.4V
- 19 -
Publication Release Date: April 13, 2005
Revision 1.1