8.4 Configuration Register (C)
BIT FLAG NAME
DESCRIPTION
D7 ALERT mask If set to ‘1’ ALERT interrupts are masked.
D6 Reserved
Reserved
D5 0
No definition and can be read out to 0.
D4 Remote
If set to ‘1’ Remote T _ CRIT _ A interrupts are masked.
T _ CRIT _ A
mask
D3 0
No definition and can be read out to 0.
D2 Local
If set to ‘1’ Local T _ CRIT _ A interrupts are masked.
T _ CRIT _ A
mask
D1 0
No definition and can be read out to 0.
D0 Reserved
Reserved
8.5 T_CRIT Hysteresis Register (TH)
REGISTER: TH
BIT D7
D6
D5
D4
VALUE 0
0
0
16
Unit: ℃
MAXIMUM VALUE: 31
D3
D2
D1
D0
8
4
2
1
8.6 Conversion Rate Register (CR)
REGISTER: CR
DEFAULT CONVERSION RATE: 16HZ
BIT<D7:D0>
0
(DECIMAL)
1
2
3
4
5
6
7
CONVERSION 31.25 mHz 62.5 mHz 125 mHz 250 mHz 500 Hz 1 Hz
2 Hz
4 Hz
RATE
(32 Sec) (16 Sec) (8 Sec) (4 Sec) (2 Sec) (1 Sec) (0.5 Sec) (0.25 Sec)
BIT<D7:D0>
8
9
(DECIMAL)
10-255
CONVERSION
RATE
8 Hz
(125
mSec)
16 Hz
(62.5
mSec)
Reserve
- 14 -
Publication Release Date: March 06
Revision 0.7