English
Language : 

W83L771W Datasheet, PDF (15/25 Pages) Winbond – H/W Monitoring IC
W83L771W/G
7.7 Fault Detect
Table 7.7 shows the response of Fault Detection if false connection of DPLUS and DMINUS occurs
after power up. Except response of Table 7.7, if false connection takes place after power up Fault
Detect, the OPEN flag will remain low and get a remote temperature -30℃, the lowest temperature
W83L771W/G could measure.
Table 7.7 response of Fault Detect
CONNECTION
(DPLUS, DMINUS)
(VDD, Floating)
(GND, Floating)
(Floating, Floating)
Shot
STATUS REGISTER BIT
(OPEN)
1
0
1
0
MEASURED REMOTE
TEMPERATURE
+128 ℃
- 128 ℃
+128 ℃
- 128 ℃
ALERT & T _ CRIT _ A
PIN
Pull Low
Pull Low
Pull Low
Pull Low
7.8 Conversion Rate and Moving Average
W83L771W/G provides an embedded moving average into conversion rate selection. The lower
conversation rate can get more average times of measured remote temperature. Using an averaging
temperature attains excellent noise rejection.
- 11 -
Publication Release Date: March 31, 2006
Revision 0.7