W83L771W Datasheet, PDF (12/25 Pages) Winbond – H/W Monitoring IC
W83L771W/G
High Limit
Measured Tmperature By
W83L771W
ALERT mask set in response to
Alert Response Address from
master
W83L771W ALERT Pin
End of Temperature conversion
W83L771W High Limit Status
Fig. 7.3.3 Response of ALERT output interrupt mode
7.4 T _ CRIT _ A Output and T_CRIT flags
T _ CRIT _ A Output pulls low when the measured temperature exceeds the critical temperature
(T_CRIT) defined in 19h, and 20h for Remote, and Local T_CRIT set point, respectively. Once the
T _ CRIT _ A Output pulls high, it will not be reset until measured temperature is lower than (T_CRIT
- TH), where TH is Temperature Hysteresis. The Status Register will not be reset until it is read and
the temperature conversion falls below the T_CRIT set point. Figure 7.4 shows this mechanism.
T_CRIT Set Point
TH Value
T_CRIT - TH
Measured Tmperature By
W83L771W
W83L771W T_CRIT_A Pin
W83L771WT_CRIT Status
*
W83L771W Read Command
for Status Register
Fig. 7.4 Response of T _ CRIT _ A output
Publication Release Date: March 06
-8-
Revision 0.7