English
Language : 

8432210000 Datasheet, PDF (44/58 Pages) Weidmuller – Mini Coupler / Mini Conditioner
Current Monitoring
WAVECONTROL
input and output range
adjustable via DIP switch
no calibration required
cross-connectable voltage
supply via cross-connectors
true TRMS value measurements
hall sensor measurement
method
Approvals:
Block diagram
WAS2 CMA
WAZ2 CMA
40/50/60A ac/dc
selectable with
analogue output
0 ... 20 mA/
4 ... 20 mA/
0 ... 10 V
Ordering data
Screw connection
Tension clamp connection
Technical data*
Input
Input current
Input frequency
Accuracy
Measuring principle
Connection type
Pass through diameter
Measurement circuit voltage
Max. measuring circuit
Output
Current/voltage selectable
Output voltage
Offset voltage
Load resistance
Output signal limit
Output current
Offset current
Load resistance
Status LED
Temperature coefficient
Response time (10 ... 90%)
Coordination of insulation acc. to DIN EN 50178, 04/98
(safe separation)
Rated voltage
Surge voltage
Overvoltage category
Contamination class
Clearance and creepage distance
Test voltage
General
Supply
Supply voltage
Power consumption at rated voltage
Reverse polarity protection
Operating temperature range
Storage/transport
Factory setting
Dimensions L/H/W (mm)
Weight
Approvals
Dimensions and accessories see
* TU = 23 °C single module
Type
Cat. No.
Qty.
WAS2 CMA 40/50/60A uc
8513330000
1
WAZ2 CMA 40/50/60A uc
8526590000
1
40/50/60A uc selectable (without additional adjustment)
0 Hz - 2 kHz (True RMS to DC Converter)
1% (0Hz - 1KHz) Crest factor 3 FSR
2% (0Hz - 2KHz) Crest factor 5 FSR
Contact-free current monitoring using Hall sensor
Push-through connection
8 mm
400 Vac, higher voltages dependent on wire insulation
dependent on wire cross-section
0 ... 10 V
0 ... 20 mA
4 ... 20 mA
0 ... 10V
max. 0.08 V
≥ 1 kΩ
approx. 13 V and. 24 mA
0/4 ... 20 mA
max.150 µA
≤ 600 Ω
green LED
ON–> OK; blinks –> signal out of range; OFF –> Error
≤ 650 ppm/K
type 700 ms
300 V
6 KV
lll
2
≥ 5.5 mm
4 kV eff
21.6 Vdc...24 Vdc...26.4 Vdc
50 mA at I out = 20 mA
yes
0 ... 50ºC
-20 ... +70ºC
0 ... 50 A uc; 4 ... 20 mA
92.4/112.4/22.5
150 g
CE, cUL
Page 298 + 308