English
Language : 

8447130000 Datasheet, PDF (34/58 Pages) Weidmuller – Mini Coupler / Mini Conditioner
RTD-Signal Isolating Transformer (Configurable)
NEW
WAVEANALOG PRO RTD
measurement from PT 100,
Ni 100, R, potentiometer
univerally adjustable via DIP switch
3-way-isolation
status LED
linearization
cross-connectable voltage supply
via cross-connectors
PRO RTD
Approvals:
Block diagram
Adjustment help
WAVETOOL
This service tool
enables quick and
uncomplicated config-
uration of
WAVEANALOG PRO.
Download from
Internet:
http:
//www.weidmueller.de
→ Products →
Downloads
(see page 192)
Ordering data
Screw connection
Tension clamp connection
Input/output
Type
WAS5 PRO RTD
WAZ5 PRO RTD
configurable
Cat. No.
8560700000
8560710000
Technical data*
Input (adjustable)
Output (adjustable)
Output voltage
Offset voltage
Load resistance
Output current
Offset current
Load resistance
Accuracy, slow/fast step response
Step response (switchable via DIP switch)
RTD, R
Potentiometer
Temperature coefficient
measurement range ≥ 200 K
100 K ≤ measurement range < 200 K
40 K ≤ measurement range < 100 K
Max. wire resistance:
Influence of wire resistances:
Open circuit recognition:
Range of man. fine adjustment
Status LED:
General
Supply voltage
Power consumption
Current carrying capacity of cross-connection
Operating temperature
Storage temperature
Factory setting
Dimensions L/H/B mm
Weight
Approvals
Coordination of insulation according to DIN EN 50178, 04/98
Rated voltage
Surge voltage
Overvoltage category
Contamination class
Clearance and creepage distance
Test voltage
PT100/2-/3-/4-wire: -200°C to 850°C
Ni100 : -60°C to +250°C
Potentiometer: min: 0…100Ω / max:0…100kΩ
Resistance: 0 ... 450Ω /
0...10 V
max. 0.05 V
≥ 1 kΩ
0/4 ... 20 mA
max. 100 µA
≤ 600 Ω
PT 100,Ni 100: 0.3% of measurement range 0.8%,
Measurement range < 100 K / 0.3 K / 0.8 K
Potentiometer: 0.2% of FS / 0.3%
Resistance: 0.2% of FS / 0.3%
typ.
fast
slow
< 1.2 s
< 2.2 s
< 500 ms
< 1.1 s
≤ 200 ppm / °C
≤ 250 ppm / °C
≤ 400 ppm / °C
50 Ω for 3- and 4-wire
max. + 0.25°C at 50 Ω wire resistance
Output signal > 10 V or > 20 mA, LED blinks
≥ ± 5%, from ver. 1: ≥12.5%, potentiometer ≥ 12.5 %…25 %
Module active: LED lit / open circuit: LED blinks
Error: LED off
18 Vdc ... 24 Vdc ... 30 Vdc
830 mW ... 880 mW ... 980mW @ Iout = 20 mA
≤2A
0...55°C
-20...85°C
PT 100/3 0 ... 100 °C / 4 ... 20 mA
No manual fine adjustment; slow step response
92.4 / 112.5 / 17.5
approx. 100 g
CE, cUL, GL
300 V
4 kV
III
2
3 mm
2 kVeff
Standards/specifications
EMC standards
Dimensions and accessories see
* TU = 23 °C single module
EN 50178, IEC751
EN 50081, EN50082, EN55011
Page 298 + 308
Selection of input
Input
Switch 1
123
PT100 2-wire
PT100 3-wire
PT100 4-wire.
R 2-wire
NI100 2-wire
NI100 3-wire
NI100 4-wire
Potentiometer
= on
= off
␽min
0°C
-10°C
-20°C
-25°C
-30°C
-40°C
-50°C
-60°C
-70°C
-80°C
-90°C
-100°C
-150°C
-200°C
Selection of minimum input values
Rmin
Pot.min
Switch 1
4567
0Ω
0%
10 Ω
10%
20 Ω
20%
20 Ω
25%
30 Ω
30%
40 Ω
40%
50 Ω
50%
60 Ω
60%
70 Ω
70%
80 Ω
80%
90 Ω
100 Ω
150 Ω
200 Ω
Special range
T
40K
50K
60K
70K
80K
90K
100K
110K
120K
125K
130K
140K
150K
160K
170K
180K
190K
200K
250K
300K
350K
400K
450K
500K
550K
600K
650K
700K
750K
800K
850K
900K
Selection of the measurement range
R
pot.
Switch 2
12345
20Ω
20%
25Ω
25%
30Ω
30%
35Ω
35%
40Ω
40%
45Ω
45%
50Ω
50%
55Ω
55%
60Ω
60%
62.5Ω 62.5%
65Ω
65%
70Ω
70%
75Ω
75%
80Ω
80%
85Ω
85%
90Ω
90%
95Ω
95%
100Ω
100%
125Ω
---
150Ω
---
175Ω
---
200Ω
---
225Ω
---
250Ω
---
275Ω
---
300Ω
---
325Ω
---
350Ω
---
375Ω
---
400Ω
---
425Ω
---
450Ω
---
Selection of output
Switch 2
Output
67
0...10V
0...20mA
4...20mA
Switching on the
manual fine adjustment
S.1
man. adj..
8
off
on
Selection of
step set time
Time of
S.2
step response
8
slow
fast
189