English
Language : 

PSMAD100 Datasheet, PDF (4/8 Pages) Wall Industries,Inc. – AC/DC Power Supplies
Wall Industries, Inc.
Rev C
PSMAD100 SERIES
100 Watt, Medical AC/DC Power Supplies
CHARACTERISTIC CURVES
Derating Curve vs Ambient Temperature
120
100
80
60
40
20
Natural Convection
0
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Ambient Temperature (°C)
Derating Curve vs Input Voltage
120
100
80
60
40
20
0
85 90 95 100 105 110 115
≈
264
Input Voltage (VAC)
Efficiency vs Input Voltage
92
90
88
86
84
82
80
85
Iout = 100% F.L.
Iout = 50% F.L.
90 110 130 150 170 190 210 230 250 264
Input Voltage (VAC)
Efficiency vs Output Load
94
92
90
88
86
84
Vin = 115VAC
Vin = 230VAC
82
10 20 30 40 50 60 70 80 90 100
% of Full Load
MECHANICAL DRAWING
3.00 (76.2)
2.750 (69.80)
1
3
Ø0.13 (Ø3.2)
TOP VIEW
FRONT VIEW
OPEN FRAME MODELS (SUFFIX “-O”)
4
1
Voltage Adj.
0.10 (2.5) max.
CON 1 - Input Connector
Pin 1
Line
Pin 3
Neutral
Mates with JST housing VHR-3N
and JST Series SVH-21T-P1.1
crimp terminals
CON 2 - Output Connector
Pins 1, 2
-Vout
Pins 3, 4
+Vout
Mates with JST housing VHR-4N
and JST Series SVH-21T-P1.1
crimp terminals
Mounting holes marked with must be connected to safety earth
SIDE VIEW
NOTES
1. Unit: inches (mm)
2. Tolerance: X.XX±0.02 (X.X±0.5)
X.XXX±0.01 (X.XX±0.25)
3. Pin Pitch Tolerance: ±0.01 (±0.25)
4. Pin Dimension Tolerance: ±0.004 (±0.1)
5. M3x0.5 screw locked torque MAX 5Kgf.cm/0.49N.m
6. All dimensions are for reference only
05/22/2013
Wall Industries, Inc. • 5 Watson Brook Road, Exeter, NH 03833 • Tel: 603-778-2300 • Toll Free: 888-597-9255 • Fax 603-778-9797
website: www.wallindustries.com • e-mail: sales@wallindustries.com
Page 4 of 8