English
Language : 

CMA3000-D0X Datasheet, PDF (21/35 Pages) VTI technologies – 3-axis accelerometer
CMA3000-D0X Series
5.3.3 SPI AC characteristics
The AC characteristics of the CMA3000 SPI interface are defined in Figure 11 and in Table 10.
TLS1
TCH
TCL
TLS2
TLH
CSB
SCK
THOL
TSET
MOSI
MSB in
DATA in
LSB in
TVAL1
TVAL2
TLZ
MISO
MSB out
DATA out
LSB out
Figure 11. Timing diagram for SPI communication.
Table 10. AC characteristics of SPI communication.
No. Parameter
Terminal CSB, SCK
1
Time from CSB (10%) to
SCK (90%) (1
2
Time from SCK (10%) to
CSB (90%) (1
Terminal SCK
3 SCK low time
4 SCK high time
5 SCK Frequency
Conditions
Load capacitance
at MISO < 50 pF
Load capacitance
at MISO < 50 pF
Terminal MOSI, SCK
6 Time from changing MOSI
(10%, 90%) to SCK (90%)
Data setup time
7 Time from SCK (90%) to
changing MOSI (10%, 90%)
Data hold time
Terminal MISO, CSB
8 Time from CSB (10%) to
stable MISO (10%, 90%)
9 Time from CSB (90%) to
high impedance state of
MISO (1.
Terminal MISO, SCK
10 Time from SCK (10%) to
stable MISO (10%, 90%) (1.
Terminal MOSI, CSB
11 Time between SPI cycles,
CSB at high level (90%)
1) Tper is SCK period
Load capacitance
at MISO < 50 pF
Load capacitance
at MISO < 50 pF
Load capacitance
at MISO < 50 pF
Symbol
TLS1
TLS2
TCL
TCH
fsck =
1/Tper
TSET
Min
Typ
0.80*
Tper/2
0.80*
Tper/2
0.80*
Tper/2
0.80*
Tper/2
Tper/2
Tper/2
Tper/4
THOL
Tper/4
TVAL1
TLZ
TVAL2
TLH
11 * Tper
Max
Unit
ns
ns
ns
ns
0.5
MHz
ns
ns
Tper/4
ns
Tper/4
ns
1.5*Tper/4
ns
ns
5.3.4
I2C AC characteristics
Please, see Phillips Semiconductors, The I2C bus specification, Version 2.1, January 2000, pp. 31-
33.
VTI Technologies Oy
www.vti.fi
Doc.Nr. 8281000.12
21/ 35