Vishay Siliconix
SPECIFICATIONSa
Parameter
Analog Switch
Analog Signal Rangee
Drain-Source On-Resistance
Source Off Leakage Current
Drain Off Leakage Current
Channel On Leakage Currentf
Digital Control
Input Current with
Input Voltage High
Input Current with
Input Voltage Low
Dynamic Characteristics
Turn-On Time
Turn-Off Time
Charge Injection
Source Off Capacitance
Drain Off Capacitance
Channel-On Capacitance
Off Isolation
Crosstalk (Channel-to-Channel)
Power Supplies
Positive Supply Current
Negative Supply Current
Symbol
VANALOG
rDS(on)
IS(off)
ID(off)
ID(on)
IINH
IINL
tON
tOFF
Q
CS(off)
CD(off)
CD(on)+
CS(on)
OIRR
XTALK
I+
I-
Test Conditions
Unless Otherwise Specified
V+ = 15 V, V- = - 15 V
VIN = 2.4 V, 0.8 Vf
VD = ± 10 V, IS = - 1 mA
VS = ± 14 V, VD = 14 V
VD = ± 14 V, VS = 14 V
VS = VD = ± 14 V
VIN = 2.4 V
VIN = 15 V
VIN = 0 V
See Switching Time Test Circuit
CL = 1000 pF, Rg = 0 Ω, Vg = 0 V
f = 140 kHz
VS = 0 V
VIN = 5 V
VD = 0 V
VS = VD = 0 V, VIN = 0 V
VIN = 5 V, RL = 75 Ω
VS = 2 V, f = 1 MHz
Both Channels On or Off
VIN = 0 V and 5.0 V
Limits
- 40 to 85 °C
Tempb Minc Typd Maxc Unit
Full
- 15
15
V
Room
Full
45
85
100
Ω
Room
Full
-2
- 100
± 0.01
2
100
Room
Full
-2
- 100
± 0.01
2
100
nA
Room - 2
Full - 200
± 0.1
2
200
Room
Full
- 0.5 0.0009
-1
Room
Full
0.005
0.5
1
µA
Room - 0.5 - 0.0015
Full
-1
Room
Room
Room
Room
Room
Room
Room
Room
300 1000
ns
200
425
1
pC
5
5
pF
16
90
dB
95
Room
Room - 10
50
µA
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25 °C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f. VIN = input voltage to perform proper function.
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation
of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum
rating conditions for extended periods may affect device reliability.
Document Number: 71357