English
Language : 

WBP Datasheet, PDF (2/6 Pages) Vishay Siliconix – High voltage, current, and temperature range
www.vishay.com
WBP
Vishay Dale
ABSOLUTE MAXIMUM RATINGS (all voltages referenced to GND = 0 V)
PARAMETER
UNIT
RATING
Vsup / Vmeas
V
LIN
V
-22 to +40
-16 to +40
LIN short-circuit current
mA
200
IN+
mV
-200 to +300
IN-
mV
Operating temperature (1)
°C
-200 to +300
-40 to +115
Storage temperature
°C
+150
Note
• Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability
RECOMMENDED OPERATING RANGE (all voltages referenced to GND = 0 V)
PARAMETER
UNIT
RATING
Vsup (1) / Vmeas
V
IN+
mV
4 to 18
± 200
IN-
mV
Operating temperature (2)(3)
°C
±5
-40 to +105
Notes
(1) LIN interface requires at least 7 V for functionality
(2) Temperature as measured by WBP output
(3) Reduced functionality above 105 °C may be experienced
CURRENT VALUE PER GAIN RANGE
RANGE
LOWEST I
(± A)
HIGHEST I
(± A)
RESOLUTION
(mA)
1
0.0000
23.0718
0.7153
2
23.0719
46.1436
1.4305
3
46.1437
92.2873
2.8611
4
92.2874
184.5747
5.7222
5
184.5748
369.1495
11.4444
6
369.1496
738.2992
22.8887
7
738.2993
1476.5984
45.7775
8
1476.5985
2000.0000
91.5550
TEMPERATURE ACCURACY
MAXIMUM CURRENT ERROR (CONTINUOUS)
3.5
3
2.5
2
1.5
1
0.5
0
0
200
400
600
Current Read (± A)
MAXIMUM CURRENT ERROR (FULL RANGE)
12
10
8
6
4
2
0
0
500
1000
1500
Current Read (± A)
2000
Revision: 05-Jan-17
2
Document Number: 30194
For technical questions, contact: ww2cresistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000