English
Language : 

V23990-K220-A40-PM Datasheet, PDF (6/17 Pages) Vincotech – Trench Fieldstop IGBT4 technology
V23990-K220-A40-PM
T1,T2,T3,T4,T5,T6,T7/D1,D2,D3,D4,D5,D6,D7
Figure 9
Typical switching times as a
function of collector current
t = f(IC)
1
tf
0,1
0,01
T1,T2,T3,T4,T5,T6,T7 IGBT
Figure 10
Typical switching times as a
function of gate resistor
t = f(RG)
1
tdoff
0,1
tdon
tr
0,01
T1,T2,T3,T4,T5,T6,T7 IGBT
tdoff
tdon
tf
tr
0,001
0
0,001
15
30
45
60
I C (A)
75
0
15
30
45
60
R G ( Ω ) 75
With an inductive load at
Tj =
150
°C
VCE =
600
V
VGE =
±15
V
Rgon =
8
Ω
Rgoff =
8
Ω
With an inductive load at
Tj =
150
°C
VCE =
600
V
VGE =
±15
V
IC =
35
A
Figure 11
Typical reverse recovery time as a
function of collector current
trr = f(IC)
0,8
0,6
D1,D2,D3,D4,D5,D6,D7 FWD
trr
Figure 12
Typical reverse recovery time as a
function of IGBT turn on gate resistor
trr = f(Rgon)
0,8
D1,D2,D3,D4,D5,D6,D7 FWD
trr
Tj = Tjmax -25°C
0,6
Tj = Tjmax -25°C
Tj = 25°C
trr
0,4
0,4
0,2
0,2
Tj = 25°C
trr
0
0
0
15
30
45
60
I C (A) 75
0
15
30
45
60
R gon ( Ω ) 75
At
Tj =
VCE =
VGE =
Rgon =
25/150 °C
600
V
±15
V
8
Ω
At
Tj =
VR =
IF =
VGE =
25/150 °C
600
V
35
A
±15
V
copyright Vincotech
6