English
Language : 

V23990-K203-A-PM Datasheet, PDF (6/17 Pages) Vincotech – Trench Fieldstop IGBT3 technology
V23990-K203-A-PM
datasheet
T1,T2,T3,T4,T5,T6,T7 / D1,D2,D3,D4,D5,D6,D7
Figure 9
Typical switching times as a
function of collector current
t = f(IC)
1
tf
0,1
0,01
tr
IGBT
tdoff
tdon
Figure 10
Typical switching times as a
function of gate resistor
t = f(RG)
1
tdoff
0,1
tf
0,01
IGBT
tdon
tr
0,001
0
0,001
5
10
15
20
25 I C (A) 30
0
25
50
75
100
With an inductive load at
Tj =
125
°C
VCE =
300
V
VGE =
15
V
Rgon =
32
Ω
Rgoff =
16
Ω
With an inductive load at
Tj =
125
°C
VCE =
300
V
VGE =
15
V
IC =
15
A
Figure 11
Typical reverse recovery time as a
function of collector current
trr = f(IC)
0,6
0,5
Tj = Tjmax -25°C
0,4
0,3
Tj = 25°C
0,2
0,1
FWD
trr
trr
Figure 12
Typical reverse recovery time as a
function of IGBT turn on gate resistor
trr = f(Rgon)
0,5
0,4
Tj = Tjmax -25°C
0,3
Tj = 25°C
0,2
0,1
0
0
5
10
15
20Tc=80°C 25 I C (A) 30
0
0
25
50
75
100
At
At
Tj =
25/125 °C
Tj =
25/125 °C
VCE =
300
V
VR =
300
V
VGE =
15
V
IF =
15
A
Rgon =
32
Ω
VGE =
15
V
125 R G ( Ω ) 150
FWD
trr
trr
125
150
R g on ( Ω )
copyright Vincotech
6
Revision: 3