English
Language : 

PRM48BF480T400B00 Datasheet, PDF (9/22 Pages) Vicor Corporation – High Efficiency Remote Sense PRM Converter
PRM48BF480T400B00
7.0 APPLICATIONS CHARACTERISTICS
The following figures present typical performance at TC = 25ºC, unless otherwise noted. See associated figures for
general trend data.
No Load Power Dissipation vs. Line
Module Enabled - Nominal VOUT
6
5
4
3
2
1
0
38 40 42 44 46 48 50 52 54
Input Voltage [V]
TCASE:
-40 ºC
25 ºC
100 ºC
Figure 1 - No load power dissipation vs. VIN, module
enabled
Efficiency & Power Dissipation
VOUT = 20 V TCASE = -40 ºC
98
16
96
94
14
92
90
12
88
86
10
84
82
8
80
78
6
76
74
4
72
70
2
0
1
2
3
4
5
6
7
8
9
Load Current [A]
VIN:
38
45
55
38
45
55
Figure 3 – Total efficiency and power dissipation vs. VIN
and IOUT, VOUT = 20 V, TCASE = -40ºC
No Load Power Dissipation vs. Line
Module Disabled, PC=Low
1
0.8
0.6
0.4
0.2
0
38 40 42 44 46 48 50 52 54
Input Voltage [V]
TCASE:
-40 ºC
25 ºC
100 ºC
Figure 2 - No load power dissipation vs. VIN, module
disabled
Efficiency & Power Dissipation
VOUT = 48 V TCASE = -40 ºC
98
16
96
94
14
92
90
12
88
86
10
84
82
8
80
78
6
76
74
4
72
70
2
0
1
2
3
4
5
6
7
8
9
Load Current [A]
VIN:
38
45
55
38
45
55
Figure 4 – Total efficiency and power dissipation vs. VIN
and IOUT, VOUT = 48 V, TCASE = -40ºC
PRM® Regulator
Rev 1.1
800 927.9474