English
Language : 

IB0XXQ096T70XX-XX Datasheet, PDF (8/18 Pages) Vicor Corporation – 5:1 Intermediate Bus Converter Module: Up to 750W Output
IB0xxQ096T70xx-xx
Electrical Specifications (Cont.)
Specifications valid at 48VIN, 100% rated load and 25ºC ambient, unless otherwise indicated.
Environmental Qualification
• IPC-9592A, based on Class II Category 2 the following detail is applicable.
Test Description
5.2.3 HALT (Highly Accelerated Life Testing)
5.2.4 THB (Temperature Humidity Bias)
5.2.5 HTOB (High Temperature Operating Bias)
5.2.6 TC (Temperature Cycling)
5.2.7 PTC (Power & Temperature Cycling)
5.2.8 – 5.2.13 Shock and Vibration
5.2.14 Other Environmental Tests
ESD Classification Testing
Total Quantity (estimated)
Test Detail
Low temp
High temp
Rapid thermal cycling
6 DOF random vibration test
Input voltage test
Output load test
Combined stresses test
(72hr presoak required) 1000hrs – continuous bias
Power cycle – On 42 minutes
Off 1 minute, On 1 minute, Off 1 minute, On 1 minute, Off 1 minute,
On 1 minute, Off 1 minute, On 1 minute, Off 10 minutes. Alternating
between maximum and minimum operating voltage every hour.
700 cycles, 30 minute dwell at each extreme – 20C minimum ramp rate
Reference IPC-9592A
Random Vibration – Operating IEC 60068-2-64 (normal operation vibration)
Random Vibration Non-operating (transportation) IEC 60068-2-64
Shock Operating – normal operation shock IEC 60068-2-27
Free fall – IEC 60068-2-32
Drop Test 1 full shipping container (box)
5.2.14.1 Corrosion Resistance – Not required
5.2.14.2 Dust Resistance – Unpotted class II GR-1274-CORE
5.2.14.3 SMT Attachment Reliability IPC-9701 – J-STD-002
5.2.14.4 Through Hole solderability – J-STD-002
HBM testing - JESD22-A114
Min. Quanity Tested
3
3
3
3
3
3
3
30
30
30
3
3
3
3
3
1
N/A
3
N/A
5
3
138
IBC Module
Page 8 of 18
Rev 1.2
09/2016
vicorpower.com
800 927.9474