All specifications are at TJ = 25ºC unless otherwise noted. See associated figures for general trend data
Attribute
No load power
Inrush current peak
Efficiency (ambient)
Efficiency (hot – 100ºC)
Output resistance (-40ºC)
Output resistance (25ºC)
Output resistance (100ºC)
Output voltage ripple
VOUT transient voltage (positive)
VOUT transient voltage (negative)
Undervoltage lockout response time
Output overcurrent response time
Overvoltage lockout response time
Symbol
PNL
INR_P
h
h
ROUT_C
ROUT_R
ROUT_H
VOUT_PP
VOUT_TRAN+
VOUT_TRAN-
TUVLO
TOCP
TOVLO
Conditions / Notes
VIN = 48V, PC enabled
COUT = 500µF, POUT = 120W
VIN = 48V, POUT = 120W, COUT = 500µF
VIN = 48V, POUT = 120W, COUT = 500µF
VIN = 48V
VIN = 48V
VIN = 48V
COUT = 0µF, POUT = 120W @ VIN = 48V, VIN = 48V
IOUT_STEP = 0 – 10.55A, ISLEW > 10A/µs
IOUT_STEP = 10.55 – 0A, ISLEW > 10A/µs
12 < IOCP < 25A
Typ
Unit
1.75
W
6
A
95
%
94
%
35
mΩ
44
mΩ
56
mΩ
160
mV
1.4
V
1.3
V
2.4
µs
4.4
ms
2.4
µs