BCM48Bx120y120B00
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TJ ≤ 125°C (T-Grade); all other specifications are at TJ = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Input overvoltage lockout threshold
Input overvoltage recovery threshold
Input undervoltage recovery
threshold
Input undervoltage lockout
threshold
Output overcurrent trip threshold
Short circuit protection trip threshold
Short circuit protection response
time
Thermal shutdown threshold
VIN_OVLO+
VIN_OVLO-
VIN_UVLO+
VIN_UVLO-
IOCP
ISCP
TSCP
TJ_OTP
Protection
VIN = 48V, 25ºC
55.5
58.1
60
V
55.1
58.7
60
V
30.7
32.9
37.3
V
29.1
31.5
35.4
V
12
17
24
A
24
40
A
0.8
1.0
1.2
µs
125
130
135
°C
120
97
38
Figure 1 — POUT derating vs VIN
48
55
VIN (VDC)
BCM® Bus Converter
Page 5 of 20
Rev 1.3
08/2016
vicorpower.com
800 927.9474