English
Language : 

BCM4414XD1E5135YZZ Datasheet, PDF (7/41 Pages) Vicor Corporation – Isolated Fixed-Ratio DC-DC Converter
BCM4414xD1E5135yzz
Electrical Specifications (Cont.)
Specifications apply over all line and load conditions, unless otherwise noted; boldface specifications apply over the temperature range of
-40°C ≤ TCASE ≤ 100°C (T-Grade); all other specifications are at TCASE = 25ºC unless otherwise noted.
­Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Powertrain Supervisory Limits High Voltage Side to Low Voltage Side (Forward Direction)
HI Side Overvoltage Lockout
Threshold
VHI_OVLO+
420
436
450
V
HI Side Overvoltage Recovery
Threshold
VHI_OVLO-
405
426
440
V
HI Side Overvoltage Lockout
Hysteresis
VHI_OVLO_HYST
10
V
HI Side Overvoltage Lockout
Response Time
tHI_OVLO
100
µs
HI Side Undervoltage Lockout
Threshold
VHI_UVLO-
200
226
250
V
HI Side Undervoltage Recovery
Threshold
VHI_UVLO+
225
244
259
V
HI Side Undervoltage Lockout
Hysteresis
VHI_UVLO_HYST
15
V
HI Side Undervoltage Lockout
Response Time
tHI_UVLO
100
µs
HI Side Undervoltage Startup Delay
tHI_UVLO+_DELAY
From VHI_DC = VHI_UVLO+ to powertrain active, (i.e One
time Startup delay form application of VHI_DC to VLO_DC)
20
ms
LO Side Output Overcurrent Trip
Threshold
ILO_OUT_OCP
42.5
45
47.5
A
LO Side Output Overcurrent
Response Time Constant
tLO_OUT_OCP Effective internal RC filter
2
ms
Overtemperature Shutdown
Threshold
tOTP+
Temperature sensor located inside controller IC
(Internal Temperature)
125
°C
Overtemperature Recovery
Threshold
tOTP–
Temperature sensor located inside controller IC
(Internal Temperature)
105
110
115
°C
Undertemperature Shutdown
Threshold
tUTP
Temperature sensor located inside controller IC;
Protection not available for M-Grade units.
-45
°C
Undertemperature Restart Time
tUTP_RESTART
Startup into a persistent fault condition. Non-Latching
fault detection given VHI_DC > VHI_UVLO+
3
s
BCM® in a VIA Package
Page 7 of 41
Rev 1.4
09/2016
vicorpower.com
800 927.9474