READ_VIN Command (88h)
If PAGE data byte is equal to (01h - 04h) command will return a
reported individual BCM’s HI side voltage in the following format:
VHI_ACTUAL = VHI_REPORTED • 10 -1(V)
READ_IIN Command (89h)
If PAGE data byte is equal to (01h - 04h) command will return a
reported individual BCM’s HI side current in the following format:
IHI_ACTUAL = IHI_REPORTED • 10 -3(A)
If PAGE data byte is equal (00h) command will return the sum of
active BCM’s HI side current.
READ_VOUT Command (8Bh)
If PAGE data byte is equal to (01h - 04h) command will return a
reported individual BCM’s LO side voltage in the following format:
VLO_ACTUAL = VLO_REPORTED • 10 -1(V)
READ_IOUT Command (8Ch)
If PAGE data byte is equal to (01h - 04h) command will return a
reported individual BCM’s LO side current in the following format:
ILO_ACTUAL = ILO_REPORTED • 10 -2(A)
If PAGE data byte is equal (00h) command will return the sum of
active BCM’s LO side current.
READ_TEMPERATURE_1 Command (8Dh)
If PAGE data byte is equal to (01h - 04h) command will return a
reported individual BCM’s temperature in the following format:
TACTUAL = ±TREPORTED (°C)
BCM4414xD1E5135yzz
READ_POUT Command (96h)
If PAGE data byte is equal to (01h - 04h) command will return a
reported individual BCM’s LO side power in the following format:
PLO_ACTUAL = PLO_REPORTED (W)
If PAGE data byte is equal to (00h) command will return the sum of
active BCM’s LO side power.
MFR_VIN_MIN Command (A0h),
MFR_VIN_MAX Command (A1h),
MFR_VOUT_MIN Command (A4h),
MFR_VOUT_MAX Command (A5h),
MFR_IOUT_MAX Command (A6h),
MFR_POUT_MAX Command (A7h)
These values are set by the factory and indicate the device HI side/
LO side voltage and LO side current range and LO side power
capacity.
The internal µC will report rated BCM HI side voltage minimum
and maximum in Volts, LO side voltage minimum and maximum
in Volts, LO side current maximum in Amperes and LO side power
maximum in Watts.
If PAGE data byte is equal to (00h) then:
n MFR_VIN_MIN COMMAND (A0h) will return the highest
MFR_VIN_MIN of all active BCMs
n MFR_VIN_MAX COMMAND (A1h) will return the lowest
MFR_VIN_MAX of all active BCMs
n MFR_VOUT_MIN COMMAND (A4h) will return the highest
MFR_VOUT_MIN of all active BCMs
n MFR_VOUT_MAX COMMAND (A5h) will return the lowest
MFR_VOUT_MAX of all active BCMs
n MFR_IOUT_MAX COMMAND (A6h) will return the SUM of
MFR_IOUT_MAX of all active BCMs
n MFR_POUT_MAX COMMAND (A7h) will return the SUM of
MFR_POUT_MAX of all active BCMs
If PAGE data byte is equal (00h) command will return the maximum
temperature of active BCM’s.
BCM® in a VIA Package
Page 34 of 41
Rev 1.4
09/2016
vicorpower.com