English
Language : 

IB048E120T32N1-00_14 Datasheet, PDF (6/16 Pages) Vicor Corporation – 4:1 Intermediate Bus Converter Module: Up to 300 W Output
IB0xxE120T32xx-xx
SPECIFICATIONS (CONT.)
IPC-9592A, Based on Class II Category 2 the following detail is applicable. – Pre-conditioning required
Environmental Qualification
Test Description
Test Detail
Quantity Tested
Low Temp
3
High Temp
3
Rapid Thermal Cycling
3
5.2.3 HALT (Highly Accelerated Life testing)
6 DOF Random Vibration Test
3
Input Voltage Test
3
Output Load Test
3
Combined Stresses Test
3
5.2.4 THB (Temp. Humidity Bias)
(72 hr presoak required) 1000 hrs – Continuous Bias
30
Power cycle - On 42 minutes
5.2.5 HTOB (High Temp. Operating Bias)
Off 1 minute, On 1 minute, Off 1 minute, On 1 minute, Off 1 minute,
30
On 1 minute, Off 1 minute, On 1 minute, Off 10 minutes. Alternating
between maximum and minimum operating Voltage every hour.
5.2.6 TC (Temp. Cycling)
700 cycles , 30 minute dwell at each extreme – 20C minimum ramp rate.
30
5.2.7 Power Cycling
Reference IPC-9592A
3
5.2.8 – 5.2.13 Shock and Vibration
Random Vibration – Operating IEC 60068-2-64 (normal operation vibration)
3
Random Vibration Non-operating (transportation) IEC 60068-2-64
3
Shock Operating - normal operation shock IEC 60068-2-27
3
Free fall - IEC 60068-2-32
3
Drop Test 1 full shipping container (box)
12
5.2.14.1 Corrosion Resistance – Not required
N/A
5.2.14.2 Dust Resistance – Unpotted class II GR-1274-CORE
3
5.2.14 Other Environmental Tests
5.2.14.3 SMT Attachment Reliability IPC-9701 - J-STD-002
3
5.2.14.4 Through Hole solderability – J-STD-002
5
ESD Classification Testing
Sample size assumes CDM testing
12
Total Quantity (est.)
161
IBC MODULE
Page 6 of 16
Rev 1.0
03/2015
vicorpower.com
800 927.9474