English
Language : 

IB048E120T32N1-00_14 Datasheet, PDF (14/16 Pages) Vicor Corporation – 4:1 Intermediate Bus Converter Module: Up to 300 W Output
IB0xxE120T32xx-xx
IBC BLOCK DIAGRAM
The Sine Amplitude Converter TM (SAC )TM uses a high frequency resonant tank to transfer energy from input to output. The resonant tank is formed by Cr and
leakage inductance from the main transformer, Lr, as shown in the block diagram. The controller regulates switching frequency of the FET drivers, monitors
current sensing, and provides undervoltage and overvoltage protection.
Figure 31 — IBC Block diagram
IBC MODULE
Page 14 of 16
Rev 1.0
03/2015
vicorpower.com
800 927.9474