SPECIFICATIONS (CONT.)
Electrical Characteristics (Continued)
Attribute
Symbol
Conditions / Notes
OUTPUT CONT.
Pre-bias voltage
Unit will start up into a pre-bias
voltage on the output.
IB0xxE120T32xx-xx
Min
Typ
Max
Unit
0
15
Vdc
Control & Interface Specifications
Attribute
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Enable (negative logic)
Module enable threshold
Module enable current
Module disable threshold
Module disable current
Disable hysteresis
Enable pin open circuit voltage
EN to –IN resistance
Enable (positive logic)
Module enable threshold
Module disable threshold
EN source current (operating)
EN voltage (operating)
Referenced to –IN
VEN = 0.8 V
0.8
Vdc
130
200
µA
2.4
Vdc
VEN = 2.4 V
130
µA
500
mV
2.5
3.0
Vdc
Open circuit, 10 V applied between EN and -IN
35
kΩ
Referenced to –IN
2.0
2.5
3.0
Vdc
VEN = 5 V
1.45
Vdc
2
mA
4.7
5
5.3
Vdc
General Characteristics
Attribute
MTBF
Service life
Over temperature shut down
Dielectric withstand
Insulation resistance
Mechanical
Weight
Length
Width
Height above customer board
Pin Solderability
Moisture Sensitivity Level
Clearance to customer board
Agency approvals
Altitude, operating
Relative humidity, Operating
RoHS compliance
Conditions: 25°C case, 75% rated load and specified input voltage range unless otherwise specified.
Symbol
Conditions / Notes
Min
Typ
Max
Unit
Calculated per Telcordia SR-332, 40°C
Calculated at 30°C
TJ ; Converter will reset when over
temperature condition is removed
Input to output
Input to output
1.0
Mhrs
7
Years
125
130
135
°C
1,500
Vdc
30
MΩ
0.71 / 20.3
oz/g
2.30 /58.4
in / mm
0.9 / 22.9
in / mm
0.38 /9.5
in / mm
Storage life for normal solderability
1
Years
MSL
Not applicable, for wave soldering only
N/A
From lowest component on IBC
0.12/ 0.30
in / mm
UL/CSA 60950-1
cURus
UL/CSA 60950-1, EN60950-1
cTUVus
Derate operating temp 1°C
per 1,000 feet above sea level
-500
10,000
Feet
Non condensing
10
90
%
Compatible with RoHS directive 2002/95/EC
IBC MODULE
Page 5 of 16
Rev 1.0
03/2015
vicorpower.com