BCM400y500x1K8A31
Electrical Specifications
Specifications apply over all line and load conditions, unless otherwise noted; Boldface specifications apply over the temperature range of -40°C ≤ TINTERNAL
≤ 125°C (T-Grade); All other specifications are at TINTERNAL = 25ºC unless otherwise noted.
Attribute
Symbol
Conditions / Notes
Min
Typ
Max Unit
Input voltage range, continuous
Input voltage range, transient
VIN µController Active
Quiescent current
No load power dissipation
Inrush current peak
DC input current
Transformation ratio
Output power (continuous)
Output power (pulsed)
Output current (continuous)
Output current (pulsed)
Efficiency (ambient)
Efficiency (hot)
Efficiency (over load range)
Output resistance
Switching frequency
Output voltage ripple
Input inductance (parasitic)
Output inductance (parasitic)
Input Series inductance (internal)
Effective Input capacitance (internal)
VIN_DC
VIN_TRANS
VµC_ACTIVE
IQ
PNL
IINR_P
IIN_DC
K
POUT_DC
POUT_PULSE
IOUT_DC
IOUT_PULSE
hAMB
hHOT
h20%
ROUT_COLD
ROUT_AMB
ROUT_HOT
FSW
VOUT_PP
LIN_PAR
LOUT_PAR
LIN_INT
CIN_INT
Powertrain
Full current or power supported, 50 ms max,
10% duty cycle max
VIN voltage where µC is initialized,
(ie VAUX = Low, powertrain inactive)
Disabled, EN Low, VIN = 400 V
TINTERNAL ≤ 100ºC
VIN = 400 V, TINTERNAL = 25ºC
VIN = 400 V
VIN = 260 V to 410 V, TINTERNAL = 25ºC
VIN = 260 V to 410 V
VIN = 410 V, COUT = 100 µF,
RLOAD = 25% of full load current
TINTERNAL ≤ 100ºC
At POUT = 1750 W, TINTERNAL ≤ 100ºC
K = VOUT / VIN, at no load
10 ms pulse, 25% Duty cycle, PTOTAL = % rated POUT_DC
10 ms pulse, 25% Duty cycle, ITOTAL = % rated IOUT_DC
VIN = 400 V, IOUT = 35 A
VIN = 260 V to 410 V, IOUT = 35 A
VIN = 400 V, IOUT = 17.50 A
VIN = 400 V, IOUT = 35 A, TINTERNAL = 100°C
7 A < IOUT < 35 A, TINTERNAL ≤ 100ºC
VIN = 400 V, IOUT = 35 A, TINTERNAL = -40°C
VIN = 400 V, IOUT = 35 A
VIN = 400 V, IOUT = 35 A, TINTERNAL = 100°C
Frequency of the Output Voltage Ripple = 2x FSW
COUT = 0 F, IOUT = 35 A, VIN = 400 V,
20 MHz BW
TINTERNAL ≤ 100ºC
Frequency 2.5 MHz (double switching frequency),
Simulated lead model
Frequency 2.5 MHz (double switching frequency),
Simulated lead model
Reduces the need for input decoupling
inductance in BCM arrays
Effective value at 400 VIN
260
260
6
96.9
95.7
97.5
96.3
92
12
16
24
1.05
2
10
6
1/8
97.4
98
96.8
16
22.6
31
1.10
250
6.7
1.3
0.56
0.37
410
V
410
V
120
V
mA
4
14
21
W
15
22
A
12
4.5
A
V/ V
1750
W
2000
W
35
A
40
A
%
%
%
20
33
mΩ
39
1.14 MHz
mV
350
nH
nH
µH
µF
BCM® Bus Converter
Page 5 of 23
Rev 1.3
05/2015
vicorpower.com
800 927.9474