BCM400P500T1K8A31 Datasheet, PDF (13/23 Pages) Vicor Corporation – Fixed Ratio DC-DC Converter | |||
|
◁ |
BCM400y500x1K8A31
300
250
200
150
100
50
0
0.0 3.5 7.0 10.5 14.0 17.5 21.0 24.5 28.0 31.5 35.0
Load Current (A)
VIN:
400 V
Figure 10 â VRIPPLE vs. IOUT ; No external COUT. Board mounted
module, scope setting : 20 MHz analog BW
Figure 11 â Full load ripple, 2.2 µF CIN; No external COUT. Board
mounted module, scope setting : 20 MHz analog BW
Figure 12 â 0 Aâ 35 A transient response:
CIN = 2.2 µF, no external COUT
Figure 13 â 35 A â 0 A transient response:
CIN = 2.2 µF, no external COUT
Figure 14 â Start up from application of VIN = 400 V, 50% IOUT,
100% COUT
BCM® Bus Converter
Page 13 of 23
Rev 1.3
05/2015
Figure 15 â Start up from application of EN with pre-applied
VIN = 400 V, 50% IOUT, 100% COUT
vicorpower.com
800 927.9474
|
▷ |