English
Language : 

BCM48BH120120B00 Datasheet, PDF (4/16 Pages) Vicor Corporation – Fixed Ratio DC-DC Converter
BCM48BH120T120B00
1.0 ELECTRICAL CHARACTERISTICS (CONT.)
Specifications apply over all line and load conditions unless otherwise noted; Boldface specifications apply over the
temperature range of -40°C < TJ < 125°C (T-Grade); All other specifications are at TJ = 25º unless otherwise noted
ATTRIBUTE
SYMBOL
CONDITIONS / NOTES
MIN
TYP
MAX UNIT
TM
TM accuracy
TM gain
TM source current
TM internal resistance
External TM capacitance
TM voltage ripple
PROTECTION
Negative going OVLO
Positive going OVLO
Negative going UVLO
Positive going UVLO
Output overcurrent trip
Short circuit protection
trip current
Short circuit protection
response time
Thermal shutdown
junction setpoint
GENERAL SPECIFICATION
Isolation voltage (Hi-Pot)
Working voltage (IN – OUT)
Isolation vapacitance
Isolation resistance
MTBF
Agency approvals / standards
Actm
ATM
ITM
RTM-SNK
CTM
VTM-PP
CTM = 0 uF, VIN = 55 V, POUT = 120 W
VIN OVLO-
VIN OVLO+
VIN UVLO-
VIN UVLO+
IOCP
ISSP
VIN = 48 V, 25°C
TSSP
TJ-OTP
-5
+5
ºC
10
mV/°C
100
uA
25
40
50
kΩ
50
pF
75
180
250
mV
55.1
58.7
60
V
55.5
58.1
60
V
29.1
31.5
35.4
V
30.7
32.9
37.3
V
12
17
24
A
24
40
A
0.8
1.0
1.2
us
125
130
135
°C
VHIPOT
VWORKING
CIN-OUT
RIN-OUT
Unpowered unit
MIL HDBK 217F, 25°C, GB
cTUVus
CE Mark
2250
1350
10
1750
7.1
60
2150
CE Marked for Low Voltage Directive and ROHS recast directive, as applicable
V
V
pF
MΩ
Mhrs
BCM® Bus Converter
Page 4 of 16
Rev 1.2
07/2015
vicorpower.com
800 927.9474