English
Language : 

PI3420-00-LGIZ Datasheet, PDF (13/30 Pages) Vicor Corporation – 8 V to 18 Vin, 15 A Cool-Power ZVS Buck Regulator
PI34xx-00
PI3422-00-LGIZ (2.5 VOUT) Electrical Characteristics
Specifications apply for -40°C < TJ < 125°C, VIN =12 V, L1 = 125 nH (Note 1) unless other conditions are noted.
Parameter
Symbol
Conditions
Min
Typ
Max Unit
Switching Frequency
Fault Restart Delay
fS
tFR_DLY
Note [6]
Timing
650
kHz
30
ms
Synchronization Frequency Range
SYNCI Threshold
∆fSYNCI
VSYNCI
Sync In (SYNCI)
Relative to set switching frequency. Note [3]
50
110
%
2.5
V
SYNCO High
SYNCO Low
SYNCO Rise Time
SYNCO Fall Time
VSYNCO_HI
VSYNCO_LO
tSYNCO_RT
tSYNCO_FT
Source 1mA
Sink 1mA
20pF load
20pF load
Sync Out (SYNCO)
4.5
V
0.5
V
10
ns
10
ns
TRK Active Input Range
TRK Max Output Voltage
TRK Disable Threshold
Charge Current (Soft–Start)
Discharge Current (Fault)
Soft-Start Time
VTRK
VTRK_MAX
VTRK_OV
ITRK
ITRK_DIS
tSS
Soft Start And Tracking
Internal reference tracking range.
CTRK = 0uF
0
1.2
V
1.2
V
20
40
60
mV
-70
-50
-30
µA
6.8
mA
2.2
ms
High Threshold
Low Threshold
Threshold Hysteresis
Enable Pull-Up Voltage
(floating, unfaulted)
Enable Pull-Down Voltage
(floating, faulted)
Source Current
Sink Current
VEN_HI
VEN_LO
VEN_HYS
VEN_PU
Enable
With positive logic EN polarity
VEN_PD
IEN_SO
IEN_SK
With negative logic EN polarity
With positive logic EN polarity
With negative logic EN polarity
0.9
1
1.1
V
0.7
0.8
0.9
V
100
200
300
mV
2
V
0
V
-50
uA
50
uA
[1] All parameters reflect regulator and inductor system performance. Measurements were made using a standard PI34xx-00 evaluation board with 3 x 4”
dimensions and 4 layer, 2oz copper. Refer to inductor pairing table within Application Description section for specific inductor manufacturer and value.
[2] Regulator is assured to meet performance specifications by design, test correlation, characterization, and/or statistical process control.
[3] Output current capability may be limited and other performance may vary from noted electrical characteristics when switching frequency or
VOUT is modified.
[4] Refer to Output Ripple plots.
[5] Refer to Load Current vs. Ambient Temperature curves.
[6] Refer to Switching Frequency vs. Load current curves.
[7] Minimum 5 V between Vin-Vout must be maintained or a minimum load of 1 mA required.
Cool-Power®
Page 13 of 30
Rev 1.3
12/2015
vicorpower.com
800 927.9474