English
Language : 

PI3420-00-LGIZ Datasheet, PDF (12/30 Pages) Vicor Corporation – 8 V to 18 Vin, 15 A Cool-Power ZVS Buck Regulator
PI34xx-00
PI3422-00-LGIZ (2.5 VOUT) Electrical Characteristics
Specifications apply for -40°C < TJ < 125°C, VIN =12 V, L1 = 125 nH (Note 1) unless other conditions are noted.
Parameter
Symbol
Conditions
Min
Typ
Max Unit
Input Voltage
Input Current
Input Current At Output Short
(fault condition duty cycle)
Input Quiescent Current
Input Voltage Slew Rate
VIN_DC
IIN_DC
IIN_Short
IQ_VIN
VIN_SR
Input Specifications
Minimum 1 mA load required
VIN = 12 V, TC = 25°C, IOUT = 15 A
Note [2]
Disabled
Enabled (no load)
Note [2]
8
12
18
V
3.37
A
10
mA
2.6
mA
4.0
1
V/µs
Output Voltage Total Regulation
Output Voltage Trim Range
Line Regulation
Load Regulation
Output Voltage Ripple
Continuous Output Current Range
Current Limit
Output Specifications
VOUT_DC Note [2]
VOUT_DC Note [3]
∆VOUT(∆VIN) @25°C, 8 V <VIN <18 V
∆VOUT(∆IOUT) @25°C, 0.5 A <IOUT <15 A
VOUT_AC IOUT = 7.5 A, COUT = 8 x100µF, 20 MHz BW, Note [4]
IOUT_DC
IOUT_CL
2.465
2.5
2.535
V
2.0
2.5
3.1
V
0.10
%
0.20
%
14
mVp-p
15
A
18
A
UVLO Start Threshold
UVLO Stop Hysteresis
UVLO Stop Threshold
OVLO Start Hysteresis
UVLO/OVLO Fault Delay Time
UVLO/OVLO Response Time
Output Overvoltage Protection
Over-Temperature Fault Threshold
Over-Temperature Restart Hysteresis
VUVLO_START
VUVLO_HYS
VOVLO
VOVLO_HYS
tf_DLY
tf
VOVP
TOTP
TOTP_HYS
Protection
Number of the switching frequency cycles
+1% overdrive
Above Set VOUT
7.20
4
19.71
1.56
130
7.60
5
20.75
1.83
128
500
20
135
30
8.00
6
21.78
2.1
140
V
V
V
V
Cycles
ns
%
°C
°C
[1] All parameters reflect regulator and inductor system performance. Measurements were made using a standard PI34xx-00 evaluation board with 3 x 4”
dimensions and 4 layer, 2oz copper. Refer to inductor pairing table within Application Description section for specific inductor manufacturer and value.
[2] Regulator is assured to meet performance specifications by design, test correlation, characterization, and/or statistical process control.
[3] Output current capability may be limited and other performance may vary from noted electrical characteristics when switching frequency or
VOUT is modified.
[4] Refer to Output Ripple plots.
[5] Refer to Load Current vs. Ambient Temperature curves.
[6] Refer to Switching Frequency vs. Load current curves.
[7] Minimum 5 V between Vin-Vout must be maintained or a minimum load of 1 mA required.
Cool-Power®
Page 12 of 30
Rev 1.3
12/2015
vicorpower.com
800 927.9474