English
Language : 

VS-500 Datasheet, PDF (2/8 Pages) Vectron International, Inc – Voltage Controlled SAW Oscillator
VS-500 Voltage Controlled SAW Oscillator
Electrical Performance
Parameter
Symbol Minimum Typical Maximum Units Notes
Frequency
Nominal Frequency
Absolute Pull Range
Linearity
Gain Transfer @ 155.52 MHz (See Pg 5/6)
Gain Transfer @ 622.08 MHz (See Pg 5/6)
Temperature Stability @ 155.52 MHz
Temperature Stability @ 622.08 MHz
Supply
Voltage
Current (No Load)
Outputs
Mid Level
Swing
Current
Rise & Fall Time
Symmetry
Spurious Suppression
Jitter @ 155.52 MHz (See Pg 5/6)
Jitter @ 622.08 MHz (See Pg 5/6)
Control Voltage
Input Impedance (LV-PECL or PECL)
Input Impedance (ECL)
Modulation Bandwidth
Operating Temperature
Package Size
fN
APR
Lin
KV
KV
fSTAB
fSTAB
VCC
ICC
IOUT
tR, tF
SYM
φJ
φJ
Zc
Zc
BW
TOP
150 - 850
±50
±5
+691/+435
+434/+281
±100
±150
MHz 1,2,3
ppm 1,2,3,9/10
% 2,4,9/10
ppm/V 2,9/10
ppm/V 2,9/10
ppm
1,6
ppm
1,6
2.97/4.5 3.3/5.0 3.63/5.5
V
2,3
55
80
mA
3
VCC-1.5 VCC-1.3 VCC-1.1
V
2,3
850
mV-pp 2,3
20
mA
6
250
400
ps
5,6
45
50
55
%
2,3
50
60
dBc
6
0.440
ps-rms 6,7
0.230
ps-rms 6,8
100
10
500
-40
85
9.0 x 14.0 x 4.5
kΩ
6
kΩ
6
kHz
6
°C
1,3
mm
1. See Standard Frequencies and Ordering Information (Pg 8).
2. Parameters are tested with production test circuit below (Fig 2).
3. Parameters are tested at ambient temperature with test limits guardbanded for specified operating temperature.
4. Measured as the maximum deviation from the best straight-line fit, per MIL-0-55310.
5. Measured from 20% to 80% of a full output swing (Fig 1).
6. Not tested in production, guaranteed by design, verified at qualification.
7. Integrated across 12 kHz to 20 MHz, per GR-253-CORE Issue3.
8. Integrated across 50 kHz to 80 MHz, per GR-253-CORE Issue3.
9. Tested with Vc = 0.3V to 3.0V.
10. Tested with Vc = 0.5V to 4.5V.
(-1.3V to +2V)
tR
80%
tF
SYM = 100 x tA / tB
Vcc - 1.0V
Vcc - 1.3V
Disable, Enable
1
6
(-1.3V, Open)
2
5
(-1.3V)
3
4
(+2V)
COutput
Output
20%
tA
tB
Vcc - 1.6V
Figure 1. 10K LV-PECL Waveform
50Ω
50Ω
Test Circuit Notes:
1) To Permit 50Ω Measurement of Outputs, all DC Inputs are Biased Down 1.3V.
2) All Voltage Sources Contain Bypass Capacitors to Minimize Supply Noise.
3) 50Ω Terminations are Within Test Equipment.
Figure 2. 3.3V Test Circuit
Vectron International, 267 Lowell Rd, Hudson NH 03051-4916
Page 2 of 8
Tel: 1-88-VECTRON-1
Website: www.vectron.com
Rev: 14Nov03