English
Language : 

S-808XXC Datasheet, PDF (25/26 Pages) Seiko Instruments Inc – SUPER-SMALL PACKAGE HIGH-PRECISION VOLTAGE DETECTOR
Product specification
S-808xxC Series
2. S-80844KLUA-D2A-T2, S-80844KLY-x
Table 19
(Ta=25°C unless otherwise specified)
Item
Detection voltage*1
Release voltage
Current consumption
Operating voltage
Output current
Response time
Detection voltage
temperature
coefficient*3
Symbol
Condition
−VDET
+VDET
ISS
VDD
IOUT
tPLH


VDD=6.0 V

Output transistor, VDD=1.2 V
Nch, VDS=0.5 V VDD=2.4 V
Output transistor,
Pch, VDS=0.5 V
VDD=4.8 V

∆ − VDET
∆Ta • −VDET
Ta=−40°C to 85°C
Min.
4.295


0.95
0.23
1.60
0.36


Typ.
4.450*2

1.0

0.50
3.70
0.62

±100
Max.
4.605
4.700
3.0
10.0



60
±350
Unit
Test
circuit
V
1
µA
2
V
1
mA
3
4
µs
1
ppm/°C
*1. −VDET: Actual detection voltage value
*2. Specified detection voltage value (−VDET(S))
*3. The temperature change ratio in the detection voltage [mV/°C] is calculated by using the following equation.
[ ] [ ] [ ] ( ) ∆ − VDET mV/°C *1 = −VDET(S) Typ. V *2 × ∆ − VDET ppm/°C *3 ÷ 1000
∆Ta
∆Ta • −VDET
*1. Temperature change ratio of the detection voltage
*2. Specified detection voltage
*3. Detection voltage temperature coefficient
http://www.twtysemi.com
sales@twtysemi.com
4008-318-123
25 of 26