PARAMETER MEASUREMENT INFORMATION (continued)
CDC586
SCAS336E – FEBRUARY 1993 – REVISED APRIL 2004
CLKIN
Outputs
Operating
at CLKIN
Frequency
Outputs
Operating
at 2X CLKIN
Frequency
tphase error 10
tphase error 11
tphase error 12
tphase error 13
tphase error 14
tphase error 15
A. Output skew, tsk(o), is calculated as the greater of:
• The difference between the fastest and slowest of tphase error n (n = 10, 11, . . . 15)
B. Process skew, tsk(pr), is calculated as the greater of:
• The difference between the maximum and minimum tphase error n (n = 10, 11, . . . 15) across multiple devices
under identical operating conditions.
Figure 3. Waveforms for Calculation of tsk(o) and tsk(pr)
9