English
Language : 

BQ28550-R1 Datasheet, PDF (9/42 Pages) Texas Instruments – Single Cell Li-Ion Battery Gas Gauge
Not Recommended for New Designs
www.ti.com
bq28550-R1
SLUSAS4A – OCTOBER 2012 – REVISED SEPTEMBER 2014
Electrical Characteristics: Serial Communication Timing Characteristics (continued)
TA = –40 to +85ºC, VBAT = 2.7 V to 5.5 V; Typical values stated, where TA = 25ºC and VBAT = 3.6 V (unless otherwise noted).
Capacitance on serial interface pins SCL and SDA are 10 pF unless otherwise specified (1).
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
tsu(STOP)
t(BUF)
Setup time for stop
Bus free time between
stop and start
600
ns
1.3
μs
f(SCL)
Clock frequency
100
kHz
tsu (STA)
tw(H)
tw(L)
tf
tr
t(BUF)
SCL
SDA
td (STA)
tr
REPEATED
START
th(DAT) tsu (DAT)
Figure 1. Timing
tf
tsu(STOP)
STOP START
Copyright © 2012–2014, Texas Instruments Incorporated
Product Folder Links: bq28550-R1
Submit Documentation Feedback
9