English
Language : 

BQ27750 Datasheet, PDF (9/34 Pages) Texas Instruments – Impedance Track Battery Gas Gauge and Protection Solution for 1-Series Cell Li-Ion Battery Packs
www.ti.com
bq27750
SLUSCM7 – JUNE 2017
Instruction Flash (continued)
Typical values stated where TA = 25ºC, Min/Max values stated where TA = –40ºC to 85ºC (unless otherwise noted)
PARAMETER
TEST CONDITION
MIN
TYP MAX
IFLASHWRITE Flash-write current
TA = –40°C to 85°C
5
IFLASHERASE Flash-erase current TA = –40°C to 85°C
15
UNIT
mA
mA
6.21 Data Flash
Typical values stated where TA = 25ºC, Min/Max values stated where TA = –40ºC to 85ºC (unless otherwise noted)
PARAMETER
TEST CONDITION
MIN
TYP MAX
Data retention
10 (1)
Flash programming
write cycles
20000 (1)
tPROGWORD
Word programming
time
TA = –40°C to 85°C
40
tMASSERASE Mass-erase time
TA = –40°C to 85°C
40
tPAGEERASE Page-erase time
TA = –40°C to 85°C
40
IFLASHREAD Flash-read current
TA = –40°C to 85°C
1
IFLASHWRITE Flash-write current
TA = –40°C to 85°C
5
IFLASHERASE Flash-erase current TA = –40°C to 85°C
15
UNIT
Years
Cycles
µs
ms
ms
mA
mA
mA
(1) Assured by design
6.22 Current Protection Thresholds
Typical values stated where TA = 25ºC, Min/Max values stated where TA = –40ºC to 85ºC (unless otherwise noted)
PARAMETER
TEST CONDITION
MIN
TYP MAX
VOCD
OCD detection threshold
voltage range
VOCD = VSRP – VSRN,
PROTECTION_CONTROL[RSNS] = 1
VOCD = VSRP – VSRN,
PROTECTION_CONTROL[RSNS] = 0
–16.6
–8.3
–100
–50
ΔVOCD
OCD detection threshold
voltage program step
VOCD = VSRP – VSRN,
PROTECTION_CONTROL[RSNS] = 1
VOCD = VSRP – VSRN,
PROTECTION_CONTROL[RSNS] = 0
–5.56
–2.78
ΔVSCC
SCC detection threshold
voltage range
VSCC = VSRP – VSRN,
PROTECTION_CONTROL[RSNS] = 1
VSCC = VSRP – VSRN,
PROTECTION_CONTROL[RSNS] = 0
44.4
200
22.2
100
ΔVSCC
SCC detection threshold
voltage program step
VSCC = VSRP – VSRN,
PROTECTION_CONTROL[RSNS] = 1
VSCC = VSRP – VSRN,
PROTECTION_CONTROL[RSNS] = 0
22.2
11.1
VSCD1
SCD1 detection threshold
voltage range
VSCD1 = VSRP – VSRN,
PROTECTION_CONTROL[RSNS] = 1
VSCD1 = VSRP – VSRN,
PROTECTION_CONTROL[RSNS] = 0
–44.4
–22.2
–200
–100
ΔVSCD1
SCD1 detection threshold
voltage program step
VSCD1 = VSRP – VSRN,
PROTECTION_CONTROL[RSNS] = 1
VSCD1 = VSRP – VSRN,
PROTECTION_CONTROL[RSNS] = 0
–22.2
–11.1
VSCD2
SCD2 detection threshold
voltage range
VSCD2 = VSRP – VSRN,
PROTECTION_CONTROL[RSNS] = 1
VSCD2 = VSRP – VSRN,
PROTECTION_CONTROL[RSNS] = 0
–44.4
–22.2
–200
–100
UNIT
mV
mV
mV
mV
mV
mV
mV
Copyright © 2017, Texas Instruments Incorporated
Product Folder Links: bq27750
Submit Documentation Feedback
9