bq27425-G1
www.ti.com
SLUSAI6 – NOVEMBER 2011
Control(): 0x00/0x01
Issuing a Control( ) command requires a subsequent 2-byte subcommand. These additional bytes specify the
particular control function desired. The Control( ) command allows the system to control specific features of the
bq27425 during normal operation and additional features when the bq27425 is in different access modes, as
described in Table 2.
CNTL FUNCTION
CONTROL_STATUS
DEVICE_TYPE
FW_VERSION
HW_VERSION
PREV_MACWRITE
BAT_INSERT
BAT_REMOVE
SET_HIBERNATE
CLEAR_HIBERNATE
SET_CFGUPDATE
SEALED
RESET
SOFT_RESET
CNTL DATA
0x0000
0x0001
0x0002
0x0003
0x0007
0x000c
0x000d
0x0011
0x0012
0x0013
0x0020
0x0041
0x0042
Table 2. Control( ) Subcommands
SEALED ACCESS
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
No
No
No
DESCRIPTION
Reports the status of device.
Reports the device type (0x0410).
Reports the firmware version on the device type.
Reports the hardware version of the device type.
Returns previous MAC command code.
Forces the [BAT_DET] bit set when the [BIE] bit is 0.
Forces the [BAT_DET] bit clear when the [BIE] bit is 0.
Forces CONTROL_STATUS [HIBERNATE] to 1.
Forces CONTROL_STATUS [HIBERNATE] to 0.
Force CONTROL_STATUS [CFGUPMODE] to 1 and gauge enters
CONFIG UPDATE mode.
Places the bq27425 in SEALED access mode.
Forces a full reset of the bq27425.
Performs a soft reset to reinitialize configuration data. Forces
CONTROL_STATUS [CFGUPMODE] to 0.
Copyright © 2011, Texas Instruments Incorporated