TLE20x7I electrical characteristics at specified free-air temperature, VCC± = ±15 V (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
TLE20x7I
TLE20x7AI
TA†
UNIT
MIN TYP MAX MIN TYP MAX
VIO
Input offset voltage
25°C
Full range
20 100
180
10
25
μV
105
αVIO
Temperature coefficient of
input offset voltage
Full range
0.4
1
0.2
1 μV/°C
Input offset voltage
long-term drift (see Note 4) VIC = 0,
RS = 50 Ω
25°C
0.006
1
0.006
1 μV/mo
IIO
Input offset current
25°C
Full range
6
90
150
6
90
nA
150
IIB
Input bias current
25°C
Full range
15
90
150
15
90
150 nA
VICR
Common-mode input
voltage range
RS = 50 Ω
−11 −13
−11 −13
25°C
to
to
to
to
11
13
11
13
V
− 10.4
− 10.4
Full range
to
to
10.4
10.4
VOM +
Maximum positive peak
output voltage swing
RL = 600 Ω
RL = 2 kΩ
25°C
10.5 12.9
10.5 12.9
Full range
25°C
Full range
10
12 13.2
11
10
12 13.2
V
11
Maximum negative peak
VOM − output voltage swing
RL = 600 Ω
RL = 2 kΩ
25°C
−10.5 −13
−10.5 −13
Full range −10
− 10
25°C
− 12 −13.5
− 12 −13.5
V
Full range − 11
− 11
VO = ± 11 V, RL = 2 kΩ
25°C
5
45
VO = ± 10 V, RL = 2 kΩ Full range
2
Large-signal differential
AVD
voltage amplification
VO = ± 10 V, RL = 1 kΩ
25°C
Full range
3.5
1
38
10
45
3.5
8
38
2.2
V/μV
25°C
2
19
VO = ± 10 V, RL = 600 Ω Full range
0.5
5
19
1.1
Ci
Input capacitance
zo
Open-loop output
impedance
IO = 0
25°C
8
25°C
50
8
pF
50
Ω
Common-mode rejection
CMRR ratio
VIC = VICRmin,
RS = 50 Ω
25°C
Full range
100 131
96
117 131
113
dB
Supply-voltage rejection
VCC ± = ± 4 V to ± 18 V,
RS = 50 Ω
25°C
94 144
110 144
kSVR ratio (ΔVCC ± /ΔVIO)
VCC ± = ± 4 V to ± 18 V,
RS = 50 Ω
Full range
90
105
dB
ICC
Supply current
VO = 0,
No load
25°C
Full range
3.8 5.3
5.6
3.8 5.3
mA
5.6
† Full range is − 40°C to 105°C.
NOTE 4: Typical values are based on the input offset voltage shift observed through 168 hours of operating life test at TA = 150°C extrapolated
to TA = 25°C using the Arrhenius equation and assuming an activation energy of 0.96 eV.
8