CDC2536_14 Datasheet, PDF (8/15 Pages) Texas Instruments – 3.3V PHASE-LOCK LOOP CLOCK DRIVER
CDC2536
SCAS377E – APRIL 1994 – REVISED JULY 2004
PARAMETER MEASUREMENT INFORMATION (continued)
CLKIN
www.ti.com
Outputs
Operating
at CLKIN
Frequency
Outputs
Operating
at 2X CLKIN
Frequency
tphase error 10
tphase error 11
tphase error 12
tphase error 13
tphase error 14
tphase error 15
A. NOTES: . Output skew, tsk(o), is calculated as the greater of:
• The difference between the fastest and slowest of tphase error n (n = 10, 11, . . . 15)
B. Process skew, tsk(pr), is calculated as the greater of:
• The difference between the maximum and minimum tphase error n (n = 10, 11, . . . 15) across multiple devices
under identical operating conditions.
Figure 3. Waveforms for Calculation of tsk(o) and tsk(pr)