English
Language : 

CDC2536_14 Datasheet, PDF (6/15 Pages) Texas Instruments – 3.3V PHASE-LOCK LOOP CLOCK DRIVER
CDC2536
SCAS377E – APRIL 1994 – REVISED JULY 2004
www.ti.com
SWITCHING CHARACTERISTICS
over recommended ranges of supply voltage and operating free-air temperature, CL = 15 pF (see (1) and Figure 1, Figure 2
and Figure 3)
PARAMETER
fmax
Duty cycle
tphase
(2)
error
tjitter (RMS)
tsk(o) (2)
tsk(pr) (2)
tr
tf
FROM
(INPUT)
CLKIN↑
CLKIN↑
TO
(OUTPUT)
Y
Y↑
Y↑
MIN MAX UNIT
100
45%
500
55%
+500
200
0.5
1
1.4
1.4
MHz
ps
ps
ns
ns
ns
ns
(1) The specifications for parameters in this table are applicable only after any appropriate stabilization time has elapsed.
(2) The propagation delay, tphase error, is dependent on the feedback path from any output to FBIN. The tphase error, tsk(o), and tsk(pr)
specfications are only valid for equal loading of all outputs.
PARAMETER MEASUREMENT INFORMATION
From Output
Under Test
CL = 15pF
(see Note A)
500 W
Input
1.5 V
tphase error
Output
2V
0.8 V
tr
3V
1.5 V
0V
2V
1.5 V
tf
VOH
0.8 V
VOL
LOAD CIRCUIT FOR OUTPUTS
VOLTAGE WAVEFORMS
PROPAGATION DELAY TIMES
A. NOTES: . CL includes probe and jig capacitance.
B. All input pulses are supplied by generators having the following characteristics: PRR≤ 100 MHz, ZO = 50 Ω, tr≤ 2.5 ns,
tf≤ 2.5 ns.
C. The outputs are measured one at a time with one transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
6