LM139AQML, LM139QML
www.ti.com
SNOSAH8G – FEBRUARY 2005 – REVISED MARCH 2013
LM139A 883, QMLV & RH, SMD 5962–9673801 Electrical Characteristics DC
Parameters(1)(2) (continued)
The following conditions apply, unless otherwise specified. +V = 5V, VCM = 0V
Symbol
Parameters
Conditions
Notes Min Max
Unit
Sub-
groups
VCM
Common Mode Voltage Range +V = 30V
See (4)
See (5)
0
V+ -
(1.5)
V
1
See (4)
See (5)
0
V+ -
(2.0)
V
2, 3
VDiff
Differential Input Voltage
+V = 30V, -V =0V, +VI = 36V, -VI =
(6)
0V
500
nA
1, 2, 3
+V = 30V, -V = 0V, +VI = 0V, -VI =
(6)
36V
500
nA
1, 2, 3
(4) The input common-mode voltage or either input signal voltage should not be allowed to go negative by more than 0.3V. The upper end
of the common-mode voltage range is V+ −1.5V for Subgroup 1, or V+ −2.0V for Subgroup 2 & 3. Either or both inputs can go to +30
VDC without damage, independent of the magnitude of V+.
(5) Parameter ensured by VIO tests
(6) The value for VDiff is not data logged during Read and Record.
LM139A 883, QMLV & RH, SMD 5962–9673801 Electrical Characteristics AC Parameters(1)(2)
The following conditions apply, unless otherwise specified. +V = 5V
Symbol
Parameters
Conditions
Notes Min Max
Unit
Sub-
groups
tRLH
Response Time
tRHL
Response Time
VOD = 5mV
VOD = 50mV
VOD = 5mV
VOD = 50mV
5.0
µS
4
0.8
µS
4
2.5
µS
4
0.8
µS
4
(1) Pre and post irradiation limits are identical to those listed under AC and DC electrical characteristics except as listed in the “Post
Radiation Limits” table. These parts may be dose rate sensitive in a space environment and demonstrate enhanced low dose rate effect.
Radiation end point limits for the noted parameters are ensured only for the conditions as specified in Mil-Std-883, Method 1019,
Condition A.
(2) Low dose rate testing has been performed on a wafer-by-wafer basis, per test method 1019, condition D, MIL-STD-883, with no
enhanced low dose rate sensitivity (ELDRS) effect. Pre and post irradiation limits are identical to those listed under AC and DC electrical
characteristics, except as listed in the “Post Radiation Limits” table. Radiation end point limits for the noted parameters are ensured for
only the conditions as specified in MIL-STD-883, Method 1019, condition D.
LM139A 883, QMLV & RH, SMD 5962–9673801 Electrical Characteristics DC Parameters Delta
Values
The following conditions apply, unless otherwise specified. +V = 5V, VCM = 0V
Deltas required for S-Level, MLS (as specified on Internal Processing instructions (IPI)), and QMLV product at Group B,
Subgroup 5.
Symbol
Parameters
Conditions
Notes Min Max
Unit
Sub-
groups
VIO
± IBias
IIO
Input Offset Voltage
Input Bias Current
Input Offset Current
VO = 1.5V
VO = 1.5V
-1.0 1.0
mV
1
See(1) -15 15
nA
1
-10 +10
nA
1
(1) The direction of the input current is out of the IC due to the PNP input stage. This current is essentially constant, independent of the
state of the output so no loading change exists on the reference or input lines.
Copyright © 2005–2013, Texas Instruments Incorporated
Submit Documentation Feedback
7
Product Folder Links: LM139AQML LM139QML