English
Language : 

MSP430F5522 Datasheet, PDF (61/123 Pages) Texas Instruments – MIXED SIGNAL MICROCONTROLLER
www.ti.com
MSP430F5529, MSP430F5528, MSP430F5527, MSP430F5526
MSP430F5525, MSP430F5524, MSP430F5522, MSP430F5521
MSP430F5519, MSP430F5517, MSP430F5515, MSP430F5514, MSP430F5513
SLAS590L – MARCH 2009 – REVISED MAY 2013
DCO Frequency
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
fDCO(0,0)
fDCO(0,31)
fDCO(1,0)
fDCO(1,31)
fDCO(2,0)
fDCO(2,31)
fDCO(3,0)
fDCO(3,31)
fDCO(4,0)
fDCO(4,31)
fDCO(5,0)
fDCO(5,31)
fDCO(6,0)
fDCO(6,31)
fDCO(7,0)
fDCO(7,31)
SDCORSEL
PARAMETER
DCO frequency (0, 0)(1)
DCO frequency (0, 31)(1)
DCO frequency (1, 0)(1)
DCO frequency (1, 31)(1)
DCO frequency (2, 0)(1)
DCO frequency (2, 31)(1)
DCO frequency (3, 0)(1)
DCO frequency (3, 31)(1)
DCO frequency (4, 0)(1)
DCO frequency (4, 31)(1)
DCO frequency (5, 0)(1)
DCO frequency (5, 31)(1)
DCO frequency (6, 0)(1)
DCO frequency (6, 31)(1)
DCO frequency (7, 0)(1)
DCO frequency (7, 31)(1)
Frequency step between range
DCORSEL and DCORSEL + 1
TEST CONDITIONS
DCORSELx = 0, DCOx = 0, MODx = 0
DCORSELx = 0, DCOx = 31, MODx = 0
DCORSELx = 1, DCOx = 0, MODx = 0
DCORSELx = 1, DCOx = 31, MODx = 0
DCORSELx = 2, DCOx = 0, MODx = 0
DCORSELx = 2, DCOx = 31, MODx = 0
DCORSELx = 3, DCOx = 0, MODx = 0
DCORSELx = 3, DCOx = 31, MODx = 0
DCORSELx = 4, DCOx = 0, MODx = 0
DCORSELx = 4, DCOx = 31, MODx = 0
DCORSELx = 5, DCOx = 0, MODx = 0
DCORSELx = 5, DCOx = 31, MODx = 0
DCORSELx = 6, DCOx = 0, MODx = 0
DCORSELx = 6, DCOx = 31, MODx = 0
DCORSELx = 7, DCOx = 0, MODx = 0
DCORSELx = 7, DCOx = 31, MODx = 0
SRSEL = fDCO(DCORSEL+1,DCO)/fDCO(DCORSEL,DCO)
MIN TYP MAX UNIT
0.07
0.20 MHz
0.70
1.70 MHz
0.15
0.36 MHz
1.47
3.45 MHz
0.32
0.75 MHz
3.17
7.38 MHz
0.64
1.51 MHz
6.07
14.0 MHz
1.3
3.2 MHz
12.3
28.2 MHz
2.5
6.0 MHz
23.7
54.1 MHz
4.6
10.7 MHz
39.0
88.0 MHz
8.5
19.6 MHz
60
135 MHz
1.2
2.3 ratio
SDCO
Frequency step between tap
DCO and DCO + 1
SDCO = fDCO(DCORSEL,DCO+1)/fDCO(DCORSEL,DCO)
1.02
1.12 ratio
Duty cycle
Measured at SMCLK
40
50
60 %
dfDCO/dT
dfDCO/dVCC
DCO frequency temperature
drift (2)
DCO frequency voltage drift(3)
fDCO = 1 MHz
fDCO = 1 MHz
0.1
%/°C
1.9
%/V
(1) When selecting the proper DCO frequency range (DCORSELx), the target DCO frequency, fDCO, should be set to reside within the
range of fDCO(n, 0),MAX ≤ fDCO ≤ fDCO(n, 31),MIN, where fDCO(n, 0),MAX represents the maximum frequency specified for the DCO frequency,
range n, tap 0 (DCOx = 0) and fDCO(n,31),MIN represents the minimum frequency specified for the DCO frequency, range n, tap 31
(DCOx = 31). This ensures that the target DCO frequency resides within the range selected. It should also be noted that if the actual
fDCO frequency for the selected range causes the FLL or the application to select tap 0 or 31, the DCO fault flag is set to report that the
selected range is at its minimum or maximum tap setting.
(2) Calculated using the box method: (MAX(-40 to 85°C) – MIN(-40 to 85°C)) / MIN(-40 to 85°C) / (85°C – (–40°C))
(3) Calculated using the box method: (MAX(1.8 to 3.6 V) – MIN(1.8 to 3.6 V)) / MIN(1.8 to 3.6 V) / (3.6 V – 1.8 V)
Typical DCO Frequency, VCC = 3.0 V, TA = 25°C
100
10
DCOx = 31
1
DCOx = 0
0.1
0
1
2
3
4
5
6
7
DCORSEL
Figure 10. Typical DCO Frequency
Copyright © 2009–2013, Texas Instruments Incorporated
Submit Documentation Feedback
61
Product Folder Links: MSP430F5529 MSP430F5528 MSP430F5527 MSP430F5526 MSP430F5525 MSP430F5524
MSP430F5522 MSP430F5521 MSP430F5519 MSP430F5517 MSP430F5515 MSP430F5514 MSP430F5513