English
Language : 

OPA376 Datasheet, PDF (6/42 Pages) Burr-Brown (TI) – Precision, Low Noise, Low Quiescent Current, Operational Amplifier
OPA376, OPA2376, OPA4376
SBOS406G – JUNE 2007 – REVISED DECEMBER 2015
www.ti.com
6 Specifications
6.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)(1)
Voltage
Current
Temperature
Supply, VS = (V+) – (V–)
Signal input pin(2)
Signal input pin(2)
Output short-circuit(3)
Operating range, TA
Junction, TJ
Storage, Tstg
MIN
(V–) – 0.5
–10
–40
–65
MAX
7
(V+) + 0.5
10
Continuous
150
150
150
UNIT
V
V
mA
°C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) Input terminals are diode-clamped to the power-supply rails. Input signals that can swing more than 0.5 V beyond the supply rails should
be current limited to 10 mA or less.
(3) Short-circuit to ground, one amplifier per package.
6.2 ESD Ratings
V(ESD)
Electrostatic discharge
Human body model (HBM), per ANSI/ESDA/JEDEC JS-001,
all pins(1)
Charged device model (CDM), per JEDEC specification
JESD22-C101, all pins(2)
Machine model
VALUE
±4000
±1000
±200
(1) JEDEC document JEP155 states that 500-V HBM allows safe manufacturing with a standard ESD control process.
(2) JEDEC document JEP157 states that 250-V CDM allows safe manufacturing with a standard ESD control process.
UNIT
V
6.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
(V+) – (V–)
TA
Supply voltage
Operating temperature
MIN
2.2 (±1.1)
–40
NOM
MAX
5.5 (±2.75)
150
UNIT
V
°C
6
Submit Documentation Feedback
Copyright © 2007–2015, Texas Instruments Incorporated