English
Language : 

DRV120 Datasheet, PDF (6/16 Pages) Texas Instruments – POWER SAVING CURRENT CONTROLLED SOLENOID DRIVER
DRV120
SLVSBG3A – JUNE 2012 – REVISED AUGUST 2012
ELECTRICAL CHARACTERISTICS
VIN = 14 V, TA = -40°C to 105°C, over operating free-air temperature range (unless otherwise noted)
PARAMETER
TEST CONDITIONS
MIN
TYP
SUPPLY
Standby current
IQ
Quiescent current
EN = 0, VIN = 14 V
EN = 1, VIN = 14 V
100
300
CURRENT DRIVER
ROUT
OUT to GND resistance
IOUT = 200 mA
fPWM
PWM frequency
OSC = GND
DMAX
Maximum PWM duty cycle
DMIN
Minimum PWM duty cycle
tD
Start-up delay
Delay between EN going high until driver
enabled(1), fPWM = 20 kHz
CURRENT CONTROLLER, INTERNAL SETTINGS
1.7
15
20
100
9
25
IPEAK
Peak current
PEAK = GND
IHOLD
Hold current
HOLD = GND
CURRENT CONTROLLER, EXTERNAL SETTINGS
160
200
40
50
tKEEP (2)
Externally set keep time at peak
current
CKEEP = 1 µF
75
IPEAK
Externally set peak current
RPEAK = 50 kΩ
RPEAK = 200 kΩ
250
83
IHOLD
Externally set hold current
RHOLD = 50 kΩ
RHOLD = 200 kΩ
100
33
fPWM
Externally set PWM frequency
ROSC = 50 kΩ
ROSC = 200 kΩ
60
20
LOGIC INPUT LEVELS (EN)
VIL
Input low level
VIH
Input high level
REN
Input pull-up resistance
LOGIC OUTPUT LEVELS (STATUS)
1.65
350
500
VOL
Output low level
IIL
Output leakage current
UNDERVOLTAGE LOCKOUT
Pull-down activated, ISTATUS = 2 mA
Pull-down deactivated, V(STATUS) = 5 V
VUVLO
Undervoltage lockout threshold
4.6
THERMAL SHUTDOWN
TTSD
Junction temperature shutdown
threshold
160
TTSU
Junction temperature startup
threshold
140
www.ti.com
MAX UNIT
150
µA
400
2.5
Ω
25 kHz
%
%
50 µs
240 mA
60 mA
ms
mA
mA
kHz
1.3
V
V
kΩ
0.3
V
1 µA
V
°C
°C
(1) Logic HIGH between 4 V and 7 V. Note: absolute max voltage rating is 7 V.
(2) Either internal or external tKEEP time setting is selected to be activated during manufacturing of production version of DRV120.
6
Submit Documentation Feedback
Product Folder Links: DRV120
Copyright © 2012, Texas Instruments Incorporated