English
Language : 

BQ27621-G1_16 Datasheet, PDF (6/26 Pages) Texas Instruments – System-Side Fuel Gauge With Dynamic Voltage Correlation
bq27621-G1
SLUSBB3E – DECEMBER 2013 – REVISED JANUARY 2016
www.ti.com
I2C-Compatible Interface Communication Timing Characteristics (continued)
TA = –40°C to 85°C; typical values at TA = 30°C and VREGIN = 3.6 V (unless otherwise noted) (Force Note1)(1)
PARAMETER
TEST CONDITIONS
MIN
NOM
MAX
tw(L)
SCL pulse duration (low)
4.7
tw(H)
SCL pulse duration (high)
4
tsu(STA)
Setup for repeated start
4.7
tsu(DAT)
Data setup time
Host drives SDA
250
th(DAT)
Data hold time
Host drives SDA
0
tsu(STOP)
Setup time for stop
4
t(BUF)
Bus free time between stop and
start
Includes Command Waiting Time
66
tf
SCL/SDA fall time (1)
300
tr
SCL/SDA rise time (1)
300
fSCL
Clock frequency(2)
100
Fast Mode (400 kHz)
td(STA)
Start to first falling edge of SCL
600
tw(L)
SCL pulse duration (low)
1300
tw(H)
SCL pulse duration (high)
600
tsu(STA)
Setup for repeated start
600
tsu(DAT)
Data setup time
Host drives SDA
100
th(DAT)
Data hold time
Host drives SDA
0
tsu(STOP)
Setup time for stop
600
t(BUF)
Bus free time between stop and
start
Includes Command Waiting Time
66
tf
SCL/SDA fall time (1)
300
tr
SCL/SDA rise time (1)
300
fSCL
Clock frequency(2)
400
UNIT
µs
µs
µs
ns
ns
µs
µs
ns
ns
kHz
ns
ns
ns
ns
ns
ns
ns
µs
ns
ns
kHz
(2) If the clock frequency (fSCL) is > 100 kHz, use 1-byte write commands for proper operation. All other transactions types are supported at
400 kHz. (Refer to I2C Interface and I2C Command Waiting Time).
tSU(STA)
tw(H)
tw(L)
tf
tr
t(BUF)
SCL
SDA
td(STA)
tf
tr
th(DAT)
tsu(DAT)
tsu(STOP)
REPEATED
START
STOP
START
Figure 1. I2C-Compatible Interface Timing Diagrams
6
Submit Documentation Feedback
Product Folder Links: bq27621-G1