English
Language : 

LM3S5G56 Datasheet, PDF (586/1146 Pages) Texas Instruments – Stellaris® LM3S5G56 Microcontroller
Analog-to-Digital Converter (ADC)
Register 14: ADC Sample Sequence Input Multiplexer Select 0 (ADCSSMUX0),
offset 0x040
This register defines the analog input configuration for each sample in a sequence executed with
Sample Sequencer 0. This register is 32 bits wide and contains information for eight possible
samples.
ADC Sample Sequence Input Multiplexer Select 0 (ADCSSMUX0)
ADC0 base: 0x4003.8000
ADC1 base: 0x4003.9000
Offset 0x040
Type R/W, reset 0x0000.0000
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
reserved
MUX7
reserved
MUX6
reserved
MUX5
reserved
MUX4
Type RO
R/W
R/W
R/W
RO
R/W
R/W
R/W
RO
R/W
R/W
R/W
RO
R/W
R/W
R/W
Reset
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
15
reserved
Type RO
Reset
0
14
R/W
0
13
MUX3
R/W
0
12
R/W
0
11
reserved
RO
0
10
R/W
0
9
MUX2
R/W
0
8
R/W
0
7
reserved
RO
0
6
R/W
0
5
MUX1
R/W
0
4
R/W
0
3
reserved
RO
0
2
R/W
0
1
MUX0
R/W
0
0
R/W
0
Bit/Field
31
30:28
27
26:24
23
22:20
19
Name
reserved
MUX7
reserved
MUX6
reserved
MUX5
reserved
Type
RO
R/W
RO
R/W
RO
R/W
RO
Reset
0
0x0
Description
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
8th Sample Input Select
The MUX7 field is used during the eighth sample of a sequence executed
with the sample sequencer. It specifies which of the analog inputs is
sampled for the analog-to-digital conversion. The value set here indicates
the corresponding pin, for example, a value of 0x1 indicates the input
is AIN1.
0
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x0
7th Sample Input Select
The MUX6 field is used during the seventh sample of a sequence
executed with the sample sequencer. It specifies which of the analog
inputs is sampled for the analog-to-digital conversion.
0
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
0x0
6th Sample Input Select
The MUX5 field is used during the sixth sample of a sequence executed
with the sample sequencer. It specifies which of the analog inputs is
sampled for the analog-to-digital conversion.
0
Software should not rely on the value of a reserved bit. To provide
compatibility with future products, the value of a reserved bit should be
preserved across a read-modify-write operation.
586
January 23, 2012
Texas Instruments-Production Data