English
Language : 

TIBPLS506AC Datasheet, PDF (5/16 Pages) Texas Instruments – 13 × 97 × 8 FIELD-PROGRAMMABLE LOGIC SEQUENCER
TIBPLS506AC
13 × 97 × 8 FIELD-PROGRAMMABLE LOGIC SEQUENCER
SRPS003C – D3090, DECEMBER 1987 – REVISED NOVEMBER 1995
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage, VCC (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V
Input voltage (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Voltage applied to disabled output (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V
Operating free-air temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 75°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
NOTE 2: These ratings apply except when programming pins during a programming cycle or during diagnostic testing.
recommended operating conditions
VCC
VIH
Supply voltage
High-level input voltage, VCC = 5.25 V
VIL
Low-level input voltage, VCC = 4.75 V
IOH
High-level output current
IOL
Low-level output current
tw
Pulse duration
Clock high
Clock low
tsu
Setup time before CLK
active transition†
Input or feedback to S/R↑ inputs
Input or feedback to S/R↓ inputs‡
Input or feedback to S/R inputs
Without C-array
With C-array
th
Hold time after CLK
Input or feedback to S/R inputs
TA
Operating free-air temperature
† The active edge of CLK is determined by the programmed state of CLK polarity fuse.
‡ See the OR term loading section and Figure 3.
MIN NOM MAX UNIT
4.75
5 5.25 V
2
5.5 V
0.8 V
– 3.2 mA
16 mA
6
ns
6
12
20
ns
25
0
ns
0
25
75 °C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
MIN TYP§ MAX UNIT
VIK
VCC = 4.75 V,
II = – 18 mA
– 1.2 V
VOH
VCC = 4.75 V,
IOH = – 3.2 mA
2.4
3
V
VOL
VCC = 4.75 V,
IOL = 16 mA
0.37 0.5 V
IOZH
VCC = 5.25 V,
VO = 2.7 V
20 µA
IOZL
VCC = 5.25 V,
VO = 0.4 V
–20 µA
II
VCC = 5.25 V,
VI = 5.5 V
0.1 mA
IIH
VCC = 5.25 V,
VI = 2.7 V
20 µA
IIL
VCC = 5.25 V,
VI = 0.4 V
IO¶
VCC = 5.25 V,
VO = 0.5 V
– 0.25 mA
– 30
–130 mA
ICC
VCC = 5.25 V,
See Note 3,
Outputs open
156 210 mA
Ci
f = 1 MHz,
VI = 2 V
7
pF
Co
f = 1 MHz,
VO = 2 V
11
pF
Cclk
f = 1 MHz,
VCLK = 2 V
14
pF
§ All typical values are at VCC = 5 V, TA = 25°C.
¶ This parameter approximates IOS. The condition VO = 0.5 V takes tester noise into account. Not more than one output should be shorted at a
time and duration of the short circuit should not exceed one second.
NOTE 3: When the clock is programmed for negitive edge, then VI = 4.75 V. When the clock is programmed for positive edge, then VI = 0.
• POST OFFICE BOX 655303 DALLAS, TEXAS 75265
5